Related Experiment Video
Updated: Mar 25, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Improved liquid chromatography combined with pulsed electrochemical detection for the analysis of etimicin sulfate
Yuning Wu1,2, Wei Zhao1, Xiaoyue Zhu1
1Jiangsu Institute for Food and Drug Control, Nanjing, China.
Abstract:
This paper describes an improved liquid chromatography method combined with pulsed electrochemical detection for the analysis of etimicin sulfate. In total, 22 impurities could be separated. A TSK-GEL C18 column (250 mm × 4.6 mm i.d., 5 μm) is used, and the mobile phase is composed of 40 mL of acetonitrile and 960 mL of an aqueous solution containing trifluoroacetic acid (15 mL/L), pentafluoropropionic acid (500 μL/L), 50% sodium hydroxide (8 mL/L) and sodium sulfate (1.5 g/L). The pH of the aqueous solution is adjusted to 3.5 with 0.8 M sodium hydroxide. The influence of the different chromatographic parameters on the separation was investigated. A quadruple potential-time waveform was applied to the electrodes of the detection cell. 0.8 M sodium hydroxide was added post column to raise the pH to at least 12 before detection. A central composite experimental design was used to describe the relationship between factors and response values and to establish factorial analysis. Compared to previously published investigations, this improved method shows higher sensitivity, better separation ability and robustness and has been incorporated by the Chinese Pharmacopoeia 2015 for analysis of etimicin sulfate. A number of commercial samples of etimicin sulfate were also analyzed using this method.
More Related Videos
09:58Spatial Quantification of Drugs in Pulmonary Tuberculosis Lesions by Laser Capture Microdissection Liquid Chromatography Mass Spectrometry LCM-LC/MS
Published on: April 18, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Ion-Exchange Chromatography
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...