Related Experiment Video
Updated: Mar 25, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Evaluation of thermally pretreated silica stationary phases under hydrophilic interaction chromatography conditions
Mélanie Mignot1, Aurélie Périat2, Valérie Peulon-Agasse1
1Normandie Univ, Laboratoire SMS-EA3233, Univ Rouen, Mont-Saint-Aignan, France.
Abstract:
Three novel hydrophilic interaction chromatography columns packed with bare silica 2.6 μm superficially porous particles were evaluated. These stationary phases undergo a different pretreatment temperature (400, 525, and 900°C) that might influence their kinetic performance and thermodynamic properties. In the first instance, we demonstrated that the performance of these columns was inferior to the commercial ones in the low plate count range (10 000 plates), but was more favorable for N values beyond 40 000 plates. Thanks to its high permeability and reasonable flow resistance (φ = 695), together with a minimum reduced heights equivalent to a theoretical plate value of only 2.4, the stationary phase pretreated at 400°C was particularly attractive for N > 70 000 plates with a remarkably low impedance value (E = 2488). In a second step, the impact of pretreatment temperature was evaluated using two mixtures of polar substances, namely nucleobases and derivatives, as well as nicotine and derivatives. Retentions and selectivities achieved on the tested stationary phases were appropriate, but selectivity differences were minor when modifying pretreatment temperature from 400 to 525°C. When we increased the pretreatment temperature up to 900°C, the surface chemistry was more seriously modified. Finally, the columns presented a good stability even at high temperature (70°C), especially for the phases pretreated at 400 and 525°C.
More Related Videos
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
Analyte Adsorption and Distribution
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...

