Related Experiment Video
Updated: Mar 24, 2026

High-Speed Human Temporal Bone Sectioning for the Assessment of COVID-19-Associated Middle Ear Pathology
Published on: May 18, 2022
Increase in the length of superficial temporal artery biopsy over 14 years
Cheryl P Au1, Neil S Sharma1, Peter McCluskey1
1Royal Prince Alfred Hospital, Sydney, New South Wales, Australia.
Background:
Giant cell arteritis is a systemic inflammatory vasculitis of large-sized and medium-sized arteries. Superficial temporal artery biopsy of at least 20 mm has traditionally been the standard length for histopathology to accurately diagnose giant cell arteritis. Recent studies suggest than a post-fixation superficial temporal artery biopsy length of 7 to 10 mm is adequate for diagnosing giant cell arteritis.
Design:
This is a retrospective observational study.
Participants Or Samples:
The participants were all patients who underwent superficial temporal artery biopsy at Royal Prince Alfred Hospital, a large tertiary teaching hospital in Sydney, Australia, from 2008 to 2014.
Methods:
Patients were identified using computerized hospital databases. Superficial temporal artery biopsy lengths were obtained from the histopathology reports.
Main Outcome Measures:
We aimed to compare the superficial temporal artery biopsy lengths performed at a large tertiary hospital over the past 7 years, to those performed from 2000 to 2005, and to determine the frequency of diagnosis of giant cell arteritis over the two time periods.
Results:
There was a total of 96 superficial temporal artery biopsies performed from 2008 to 2014. The superficial temporal artery biopsy mean (standard deviation) length was 16.0(7.3) mm. This represented a significant (P = 0.015) increase in mean superficial temporal artery biopsy length when compared with a previous audit performed from 2000 to 2005 where the mean (standard deviation) superficial temporal artery biopsy was 11.7(6.2) mm. Of the 96 TABs, 20 (20.8%) were positive for giant cell arteritis, compared with a giant cell arteritis positivity rate of 20.4% for the previous audit period from 2000 to 2005.
Conclusion:
There has been a significant improvement in the length of superficial temporal artery biopsy performed at a tertiary hospital. Despite the increase in superficial temporal artery biopsy lengths, the giant cell arteritis positivity rate has remained stable.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...