Related Experiment Video
Updated: Mar 24, 2026

Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
Imaging procedures in cochlear implant patients - evaluation of different radiological techniques
A Aschendorff1, R Kubalek2, A Hochmuth3
1a From the Department of Otorhinolaryngology, University of Freiburg, Freiburg, Germany.
Abstract:
The purpose of this study was to evaluate the feasibility and usability of different radiologic methods (single-slice computed tomography (CT), multi-slice CT and rotational tomography (RT)) for assessment of the position of cochlear implant electrodes. Cochlear implants in an isolated human temporal bone and in a complete formalin-fixed cadaver head were examined and the electrode position was determined. Subsequently, the labyrinth bone was isolated out of the cadaver head and histologically examined to compare the results of histology with imaging. Single-slice CT reliably identifies the electrode inside the human cochlea; however, due to the technically based large electrode artifact its position inside the cochlear spaces (e.g. electrode position in scala tympani or scala vestibuli) cannot be detected. Multi-slice CT of the cadaver head also showed artifacts that complicate the assessment of electrode position. Using RT the electrode artifact is small and therefore the electrode position within the cochlear spaces, scala tympani versus scala vestibuli, can be assessed. This technique was also applicable in a complete cadaver head, which is in contrast with former studies. In conclusion, CT allows the identification of electrode arrays inside the human cochlea. Multi-slice CT permits a much more precise depiction of the electrode inside the cochlea. RT alone has minimized electrode artifacts to a high extent and permits the assessment of the electrode position within the scala tympani or scala vestibuli. As RT was performed successfully in a complete cadaver head, further studies for evaluation of the intracochlear electrode position can now be performed in patients.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...