High intercorneal symmetry in corneal biomechanical metrics
XiaoBo Zheng1, FangJun Bao1, Brendan Geraghty2
1The Affiliated Eye Hospital of Wenzhou Medical University, Wenzhou, Zhejiang Province 325027 China ; The Institution of Ocular Biomechanics, Eye Hospital, Wenzhou Medical University, No. 270# Xueyuan West Road, Wenzhou City, Zhejiang Province 325027 China.
Backgroud:
To evaluate the symmetry of corneal biomechanical metrics, measured using an ocular response analyzer (ORA) and self-built corneal inflation test platform, in bilateral rabbit corneas and to investigate their relationship with physical intraocular pressure (IOPp).
Methods:
Twenty fresh enucleated eyes from ten rabbits were used for ex vivo whole ocular globe inflation. IOP was increased from 7.5 to 37.5 mmHg with 7.5 mmHg steps and biomechanical metrics were acquired using the ORA. At least 3 examinations were performed at each pressure stage. Two biomechanical metrics, corneal hysteresis (CH) and corneal resistance factor (CRF) were recorded and analyzed as a function of IOPp. Corneal specimens were then excised from the intact ocular globe and tested under inflation conditions up to 45.7 mmHg posterior pressure. The experimental pressure-deformation data was analyzed using an inverse modeling procedure to derive the stress-strain behavior of the cornea.
Results:
A comparison of corneal shape parameters showed no statistically significant difference (P > 0.05) between bilateral eyes. Similarly, there were no statistically significant differences in values of CH, CRF and corneal stiffness (as measured by the tangent modulus, Et) between bilateral eyes (CH: F = 0.94, P = 0.54; CRF: F = 4.42, P = 0.35; Et: F = 3.15, P = 0.12) at different pressure levels. IOPp was highly correlated with CRF while the relationship with CH was less pronounced.
Conclusions:
An obvious interocular symmetry in biomechanical metrics is found in this research. IOP has been shown to have important influences on the value of CRF provided by ORA.
More Related Videos
07:51Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
07:29Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
Related Concept Videos
Eccentric Axial Loading in a Plane of Symmetry
Mechanism of Ciliary Motion
The cilia are made up of microtubules in a 9+2 arrangement, with nine microtubule doublet ring bundles, surrounding a pair of central singlet microtubule bundles. The doublet microtubule bundles are...
Mechanism of Ciliary Motion