Background:
Manufacturers' recommendations on cleaning of tracheostomy tubes focus on general warning information and non-specific manual cleaning procedures. The aim of this experimental study was to evaluate different reprocessing methods and to determine the mechanical integrity and functionality of tracheostomy tubes following reprocessing.
Methods:
Sixteen cuffed or un-cuffed tracheostomy tubes obtained from hospital in-patients were reprocessed using one of the following reprocessing methods: a) manual brushing and rinsing with tap water, b) manual brushing followed by disinfection with a glutaraldehyde solution, c) manual brushing followed machine-based cleaning in a dishwasher, and d) manual brushing followed by ultrasound cleaning in a commercially available ultrasound device. Microbial burden of the tubes before and after reprocessing was assessed by measurement of microbial colony-forming units per mL (CFU/mL) of rinsing fluid. After cleaning, tracheostomy tubes were investigated for loss of functionality.
Findings:
Manual brushing and rinsing with tap water reduced microbial colonization in average by 10(2) CFU/mL, but with poor reproducibility and reliability. Complete microbial reduction was achieved only with additional chemical or machine-based thermal disinfection. Ultrasound sonification yielded no further microbial reduction after manual brushing.
Conclusion:
Manual brushing alone will not result in complete eradication of microorganism colonising cuffed or un-cuffed tracheostomy tubes. However, manual cleaning followed by chemical or thermal disinfection may be regarded as safe and reproducible reprocessing method. If a machine-based reprocessing method is used for cuffed tubes, the cuffs' ventilation hose must be secured in a safe position prior to thermal disinfection.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Suctioning II: Procedure
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...