Related Experiment Video
Updated: Mar 24, 2026

A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Extubating Extremely Preterm Infants: Predictors of Success and Outcomes following Failure
Brett J Manley1, Lex W Doyle2, Louise S Owen3
1Newborn Research Center and Neonatal Services, The Royal Women's Hospital, Parkville, Victoria, Australia; Department of Obstetrics and Gynecology, The University of Melbourne, Parkville, Victoria, Australia.
Objectives:
To identify variables that predict extubation success in extremely preterm infants born <28 weeks gestational age (GA), and to compare outcomes between those who had successful or failed extubation.
Study Design:
A secondary analysis of data from a randomized trial of postextubation respiratory support that included 174 extremely preterm infants. "Extubation success" was defined as not requiring reintubation within 7 days, and "extubation failure" the converse. Predictive variables that were different between groups were included in a multivariable logistic regression model.
Results:
Sixty-eight percent of infants were successfully extubated. Compared with those infants who had extubation failure, they had a higher GA and birth weight, were extubated earlier, were more often exposed to prolonged ruptured membranes, more often avoided intubation in the delivery room, had a higher pre-extubation pH, and had lower mean pre-extubation fraction of inspired oxygen and partial pressure of carbon dioxide (PCO2). Only GA and PCO2 remained significant in the multivariable analysis (area under a receiver operating characteristic curve = 0.81). Extubation failure was associated with death, bronchopulmonary dysplasia, severe retinopathy of prematurity, patent ductus arteriosus ligation, and longer durations of respiratory support, oxygen supplementation, and hospitalization. When adjusted for allocated treatment in the randomized trial, GA, and birth weight z-score, extubation failure remained associated with death before discharge and prolonged respiratory support and hospitalization.
Conclusions:
In extremely preterm infants, higher GA and lower pre-extubation PCO2 predicted extubation success. Infants in whom extubation failed were more likely to die and have prolonged respiratory support and hospitalization.
Trial Registration:
Australian New Zealand Clinical Trials Network: ACTRN12610000166077.
More Related Videos
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...

