Lung function in woodsmoke-exposed Guatemalan children following a chimney stove intervention
Amy P Heinzerling1, Michael J Guarnieri1, Jennifer K Mann2
1Department of Medicine, University of California San Francisco, California, USA.
Rationale:
Household air pollution (HAP) from solid fuel combustion is a major contributor to the global burden of disease, with considerable impact from respiratory infections in children. The impact of HAP on lung function is unknown.
Objectives:
The Childhood Exposure to Respirable Particulate Matter (CRECER) prospective cohort study followed Guatemalan children who participated in the Randomised Exposure Study of Pollution Indoors and Respiratory Effects (RESPIRE) trial of a chimney stove intervention to determine the effect of early childhood HAP exposure on growth of lung function.
Methods:
RESPIRE households with pregnant women or infant children were randomised to receive a chimney stove at the beginning or at the end of the 18-month trial. During CRECER, a subset of these children, as well as children from households with newly installed stoves, were followed with spirometry beginning at age 5. Biomass smoke exposure was measured using personal carbon monoxide tubes. Two-stage regression models were employed to analyse associations with lung function growth.
Measurements And Main Results:
Longitudinal peak expiratory flow (PEF) and FEV1 data were available for 443 and 437 children, respectively, aged 5-8 (mean follow-up 1.3 years). Decreases in PEF growth of 173 mL/min/year (95% CI -341 to -7) and FEV1 of 44 mL/year (95% CI -91 to 4) were observed with stove installation at 18 months compared with stove installation at birth in analyses adjusted for multiple covariates. No statistically significant associations were observed between personal HAP exposure and lung function.
Conclusions:
A significant decrease in PEF growth and a large non-significant decrease in FEV1 growth were observed with later stove installation. Additional studies including longer follow-up and cleaner stoves or fuels are needed.
More Related Videos
09:50Impact Assessment of Repeated Exposure of Organotypic 3D Bronchial and Nasal Tissue Culture Models to Whole Cigarette Smoke
Published on: February 12, 2015
10:47Isolation of Mouse Respiratory Epithelial Cells and Exposure to Experimental Cigarette Smoke at Air Liquid Interface
Published on: February 21, 2011
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulmonary Cycle: Exhalation
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
COPD: Management Using Bronchodilators and Corticosteroids