Related Experiment Video
Updated: Mar 24, 2026

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Conversion and temperature rise of remineralizing composites reinforced with inert fillers
Matej Par1, Ozren Gamulin2, Danijela Marovic3
1Private Dental Practice, Zagreb, Croatia.
Objectives:
Remineralizing experimental composites based on amorphous calcium phosphate (ACP) were investigated. The impact of curing time (20 and 40s), curing depth (1, 2, 3 and 4mm) and addition of inert fillers (barium glass and silica) on the conversion and temperature rise during curing were examined.
Methods:
Five ACP-composites and two control composites were prepared based on the light-curable EBPADMA-TEGDMA-HEMA resin. For temperature measurements, a commercial composite was used as an additional control. Conversion was assessed using FT-Raman spectroscopy by comparing the relative change of the band at 1640 cm(-1) before and after polymerization. The temperature rise during curing was recorded in real-time using a T-type thermocouple.
Results:
At 1mm depth, the ACP-composites attained significantly higher conversion (77.8-87.3%) than the control composites based on the same resin (60.5-66.3%). The addition of inert fillers resulted in approximately 5% lower conversion at clinically relevant depths (up to 2mm) for the curing time of 40s. Conversion decline through depths depended on the added inert fillers. Conversion values higher than 80% of the maximum conversion were observed for all of the ACP-composites at depths up to 3mm, when cured for 40s. Significantly higher total temperature rise for the ACP-composites (11.5-13.1 °C) was measured compared to the control composites (8.6-10.8 °C) and the commercial control (8.7 °C).
Conclusions:
The admixture of inert fillers represents a promising strategy for further development of ACP-composites, as it reduced the temperature rise while negligibly impairing the conversion.
Clinical Significance:
High conversions of ACP-composites are favorable in terms of mechanical properties and biocompatibility. However, high conversions were accompanied with high temperature rise, which might present a pulpal hazard.
More Related Videos
08:26Development of Amelogenin-chitosan Hydrogel for In Vitro Enamel Regrowth with a Dense Interface
Published on: July 10, 2014
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Additives and Fillers in Concrete
The...
Fiber Reinforced Concrete
Reinforcements in Concrete
Ferrocement