Related Experiment Video
Updated: Mar 24, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Closed chest human aortic valve removal and replacement: Technical feasibility and one year follow-up
Marco Vola1, Jean-François Fuzellier1, Salvatore Campisi1
1Cardiovascular Surgery Unit, Cardiovascular Diseases Department, University Hospital, St-Etienne, France.
Background:
Minimally invasive aortic valve replacement has so far required a minithoracotomy or a ministernotomy. We present here the first series of totally endoscopic aortic valve replacement (TEAVR).
Methods:
Between June 2013 and April 2015, 14 consecutive patients (12 males, mean age=76 ± 5.4 years) with a mean EuroSCORE II of 2.72 ± 0.03% underwent TEAVR. A five trocar setting was used in all patients: after ablation of the native valve, a Nitinol stented sutureless 3f Enable Medtronic valve, compressed into the main working trocar, was introduced into the thorax and then expanded in the aortic root.
Results:
Among the 14 patients, a thoracoscopic approach was successful in 13 (92.8%) and conversion into an open surgery using the right anterior minithoracotomy was necessary to close the aortotomy in one case. Mean cross-clamping and cardiopulmonary (CPB) times were 112 ± 18 and 161 ± 31 min, respectively. All patients left the surgical unit within 8 days after the operation without any paravalvular leakage. There was no paravalvular regurgitation, conductive block or any major adverse event at a mean follow-up of 10 ± 4 months (range 2-16).
Conclusions:
TEAVR is feasible and safe in a selected subset of patients. Closed chest surgery has the potential to become the future approach of the isolated aortic valve replacement in low risk patients but further technical refinement and larger studies are necessary to reduce operative durations and enhance reproducibility.
More Related Videos
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022