François Galonnier1,2, Olivier Traxer3, Maeva Rosec4
11 Department of Urology, Centre Hospitalier Clermont Ferrand , Clermont-Ferrand, France .
Introduction:
Over the past 20 years, the use of fluoroscopy to guide urologic surgical interventions has been constantly growing. Thus, in their daily practice, urologists and other operating room (OR) staff are exposed to X-radiation increasingly frequently. This raises questions as to the risks they encounter and the actions needed to reduce them.
Objective:
Evaluate X-ray dose exposure in the members of the surgical team and determine urologist radioprotection knowledge and practices.
Materials And Methods:
A prospective bicenter study was conducted within AFUF (French urology resident association) and in association with The French Nuclear Safety Authority/The Institute for Radiological Protection and Nuclear Safety (ASN/IRSN). Radiation exposure was measured on 12 operators using dosimeters (seven per operator), in staff-occupied locations in the OR using ionization chambers, and on anthropomorphic phantoms. A survey was used to gather information on radiation knowledge and safety practices of the AFUF members.
Results:
Annual whole-body radiation doses were low (0.1-0.8 millisieverts [mSv], mostly at around 0.3 mSv), and equivalent doses were low for the fingers (0.7-15 mSv, mostly at around 2.5 mSv), and low for the lens of the eye (0.3-2.3 mSv, mostly at around 0.7 mSv). In percutaneous nephrolithotomy, extremity doses were lower when the patient was placed in dorsal decubitus compared with ventral decubitus. Pulsed fluoroscopy reduced radiation dose exposure by a factor of 3 compared with continuous fluoroscopy with no image quality loss. Radiation safety practices were poor: only 15% of urologists wore dosimeters and only 5% had been trained in the handling of X-ray generators.
Conclusion:
In the present study, radiation exposure for urologists was low, but so was knowledge of radiation safety and optimization practices. This absence of training for radiation safety and reduction, teamed with novel techniques involving long fluoroscopy-guided interventions, could result in unnecessarily high exposure for patients and OR personnel.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Radiological Investigation I: X-ray and CT