Related Experiment Video
Updated: Aug 14, 2026

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Synchrotron-based Phase Contrast-enhanced Micro-Computed Tomography Reveals Delaminations and Material Tearing in
Amir T Moinzadeh1, Lydia Farack2, Fabian Wilde3
1Department of Endodontology, Academic Center for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University, Amsterdam, The Netherlands.
Introduction:
This study evaluated the integrity of calcium silicate sealer-based fillings made with hygro-expandable cones (HEC) that are commercially known as CPoint or Smartpoint.
Methods:
Fourteen human canines were prepared according to a standardized, conventional endodontic treatment protocol and filled with the HEC/calcium silicate sealer. Three-dimensional imaging was performed with laboratory micro-computed tomography (μCT) at its highest resolution and was compared with synchrotron phase contrast-enhanced μCT (PCE-CT) scans of the treatment extending 1-7 mm from the apex. Conventional destructive optical microscopy validated observations by comparison with virtual slices in the tomographic data.
Results:
Conventional laboratory μCT at 10-μm resolution did not reveal the existing voids and defects within the root canal fillings. PCE-CT revealed elongated interfacial delamination localized mainly at the HEC-sealer interface forming extended through-and-through gaps along the root canal filling.
Conclusions:
Endodontic studies that use conventional laboratory μCT may underestimate thin defects and delamination within root canal fillings made with HEC because of limited resolution and contrast of laboratory-based broad-spectrum low intensity x-ray sources. These limitations favor use of high-brilliance, monochromatic synchrotron-based PCE-CT to reveal the important micrometer details within large (millimeter sized) samples. PCE-CT revealed the existence of a range of significant structural defects in recently placed HEC fillings, confirmed by optical microscopy after physical sectioning. Substantial delamination spanning 20%-40% of the circumferential interface as well as other structural defects were identified within root canal fillings made of HEC and calcium silicate sealer.
More Related Videos
07:06Use of Micro X-ray Computed Tomography with Phosphotungstic Acid Preparation to Visualize Human Fibromuscular Tissue
Published on: September 5, 2019
07:29Author Spotlight: Advanced Techniques for Characterizing Tissue Mineralization in Bone Regeneration Research
Published on: September 27, 2024
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...