Related Experiment Video
Updated: Mar 24, 2026

Long-Term Catheterization of the Intestinal Lymph Trunk and Collection of Lymph in Neonatal Pigs
Published on: March 5, 2016
[Abnormal Serum Total Protein Measurement by Lipoprotein-X in an Infant with Biliary Atresia]
Insights
Lipoprotein-X (LP-X) in infants with biliary atresia interferes with total serum protein assays using the biuret method. This interference is linked to LP-X
Area of Science:
- Clinical Chemistry
- Biochemistry
- Pediatric Gastroenterology
Background:
- Cholestatic jaundice, often seen in infants with biliary atresia, is known to cause assay interference for low-density lipoprotein-cholesterol.
- The impact of Lipoprotein-X (LP-X) on other biochemical assays, particularly total serum protein, remains largely uncharacterized.
Observation:
- A case report details an 11-month-old infant diagnosed with biliary atresia presenting with jaundice since two months of age.
- Biochemical testing revealed markedly elevated total serum protein levels when measured by the biuret method, exhibiting abnormal response curves and dilution linearity.
- Agar electrophoresis confirmed the presence of Lipoprotein-X (LP-X) in the patient's serum.
Findings:
- Experiments involving ultracentrifugation and fractionation of the patient's LP-X-rich lipoprotein fraction demonstrated abnormal reactions with the biuret method.
- Specifically, normal gamma-globulin fractions showed aberrant results when incubated with the patient's LP-X-rich lipoproteins.
- These findings indicate that LP-X significantly influences total serum protein measurements performed using the biuret method in infants with biliary atresia.
Implications:
- The study highlights a critical analytical interference in total serum protein assays caused by LP-X in cholestatic infants.
- This interference may lead to inaccurate clinical interpretations and requires careful consideration in the biochemical assessment of pediatric cholestatic conditions.
- Further research is warranted to elucidate the precise mechanism of LP-X interaction with the biuret assay and to develop methods for accurate protein quantification in such cases.
Abstract:
Lipoprotein-X (LP-X) in cholestatic jaundice causes abnormal reaction in assays for low-density lipoprotein-cholesterol, but the effects on other test items are unknown. Here, we report an infant with biliary atresia showing abnormal reaction in total serum protein assay using the biuret method, and lipoprotein-X (LP-X) was then detected. In this 11-month-old female infant, jaundice was observed at 2 months old, and a diagnosis of biliary atresia was made. On biochemical tests at 12 months old, the total serum protein concentrations detected by the biuret method were very high, and the response curve and linearity of dilution were abnormal. LP-X was detected by agar electrophoresis. In addition and recovery experiments with normal serum fractionation of the patient's LP-X-rich lipoprotein fraction prepared by ultracentrifugation, normal γ-globulin fractionation showed an abnormal reaction by the biuret method. In infants with biliary atresia, we showed that the total serum protein assay by the biuret method was influenced by LP-X-rich lipoprotein, which may be caused by abnormal reaction of LP-X and γ-globulin. [Case Report].
More Related Videos
06:48Fingerprinting Cardiolipin in Leukocytes by Mass Spectrometry for a Rapid Diagnosis of Barth Syndrome
Published on: March 23, 2022
11:59Isolation of Lipoprotein Particles from Chicken Egg Yolk for the Study of Bacterial Pathogen Fatty Acid Incorporation into Membrane Phospholipids
Published on: May 15, 2019