Background:
It is not well known what is the main mechanism causing lung heterogeneity in healthy lungs under mechanical ventilation. We aimed to investigate the mechanisms causing heterogeneity of regional ventilation and parenchymal densities in healthy lungs under anesthesia and mechanical ventilation.
Methods:
In a small animal model, synchrotron imaging was used to measure lung aeration and regional-specific ventilation (sV̇). Heterogeneity of ventilation was calculated as the coefficient of variation in sV̇ (CVsV̇ ). The coefficient of variation in lung densities (CVD ) was calculated for all lung tissue, and within hyperinflated, normally and poorly aerated areas. Three conditions were studied: zero end-expiratory pressure (ZEEP) and FI O2 0.21; ZEEP and FI O2 1.0; PEEP 12 cmH2 O and FI O2 1.0 (Open Lung-PEEP = OLP).
Results:
The mean tissue density at OLP was lower than ZEEP-1.0 and ZEEP-0.21. There were larger subregions with low sV̇ and poor aeration at ZEEP-0.21 than at OLP: 12.9 ± 9.0 vs. 0.6 ± 0.4% in the non-dependent level, and 17.5 ± 8.2 vs. 0.4 ± 0.1% in the dependent one (P = 0.041). The CVsV̇ of the total imaged lung at PEEP 12 cmH2 O was significantly lower than on ZEEP, regardless of FI O2 , indicating more heterogeneity of ventilation during ZEEP (0.23 ± 0.03 vs. 0.54 ± 0.37, P = 0.049). CVD changed over the different mechanical ventilation settings (P = 0.011); predominantly, CVD increased during ZEEP. The spatial distribution of the CVD calculated for the poorly aerated density category changed with the mechanical ventilation settings, increasing in the dependent level during ZEEP.
Conclusion:
ZEEP together with low FI O2 promoted heterogeneity of ventilation and lung tissue densities, fostering a greater amount of airway closure and ventilation inhomogeneities in poorly aerated regions.
More Related Videos
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Related Concept Videos
External and Internal Respiration
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Cycle: Exhalation