Impact of micronutrients supplementation on bone repair around implants: microCT and counter-torque analysis in rats
Related Experiment Video
Updated: Mar 23, 2026

Surgical Bone Implantation Technique for Rat Tibia Models of Diabetes and Osteoporosis
Published on: July 5, 2024
Suzana Peres Pimentel1, Renato Correa Casarin1, Fernanda Vieira Ribeiro1
1Faculdade de Odontologia, Universidade Paulista, São Paulo, SP, Brasil.
Unlabelled:
The use of natural substances and micronutritional approaches has been suggested as a therapeutic alternative to benefit the bone healing associated with no side effects. Nevertheless, the influence of micronutritional interventions with therapeutic proprieties on the bone repair has yet to be intensely evaluated, and no evidence is available exploring the impact of micronutrient supplementation on the peri-implant bone healing.
Objective:
This study investigated the effect of micronutrients supplementation on the bone repair around implants.
Material And Methods:
One screw-shaped titanium implant was inserted in each tibia of each rat, which were assigned to: daily administration, for 30 d, of the placebo solution (Placebo group-n:18) or micronutrients supplementation (Micronutrients group-n:18), based on calcium, magnesium, zinc, and vitamin D3 intake. After, the animals were sacrificed. One of the implants was removed by applying a counter-torque force to evaluate the force to rupture the bone-implant interface. The other implant was evaluated by microcomputed tomography (CT) examination to determine the bone-to-implant contact (BIC) and the bone volume (BV/TV).
Results:
No statistically significant differences were observed between the groups for both counter-torque values and microCT parameters (p>0.05).
Conclusion:
Within the limits of this study, micronutrients supplementation did not provide additional benefits to the bone healing around dental implants.
More Related Videos
11:51An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
04:24Proper Positioning and Restraint of a Rat Hind Limb for Focused High Resolution Imaging of Bone Micro-architecture Using In Vivo Micro-computed Tomography