Introduction:
Errors in the process of pretransfusion testing for blood transfusion can occur at any stage from collection of the sample to administration of the blood component. The present study was conducted to analyze the errors that threaten patients' transfusion safety and actual harm/serious adverse events that occurred to the patients due to these errors.
Materials And Methods:
The prospective study was conducted in the Department Of Transfusion Medicine, Shri Maharaja Gulab Singh Hospital, Government Medical College, Jammu, India from January 2014 to December 2014 for a period of 1 year. Errors were defined as any deviation from established policies and standard operating procedures. A near-miss event was defined as those errors, which did not reach the patient. Location and time of occurrence of the events/errors were also noted.
Results:
A total of 32,672 requisitions for the transfusion of blood and blood components were received for typing and cross-matching. Out of these, 26,683 products were issued to the various clinical departments. A total of 2,229 errors were detected over a period of 1 year. Near-miss events constituted 53% of the errors and actual harmful events due to errors occurred in 0.26% of the patients. Sample labeling errors were 2.4%, inappropriate request for blood components 2%, and information on requisition forms not matching with that on the sample 1.5% of all the requisitions received were the most frequent errors in clinical services. In transfusion services, the most common event was accepting sample in error with the frequency of 0.5% of all requisitions. ABO incompatible hemolytic reactions were the most frequent harmful event with the frequency of 2.2/10,000 transfusions.
Conclusion:
Sample labeling, inappropriate request, and sample received in error were the most frequent high-risk errors.
More Related Videos
05:23Continuous Manual Exchange Transfusion for Patients with Sickle Cell Disease: An Efficient Method to Avoid Iron Overload
Published on: March 14, 2017
11:59Detection of Residual Donor Erythroid Progenitor Cells after Hematopoietic Stem Cell Transplantation for Patients with Hemoglobinopathies
Published on: September 6, 2017
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Kidney Transplant I: Introduction
Kidney Transplant III: Nursing Management
Blood Typing
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target...