Related Experiment Video
Updated: Mar 23, 2026

Biological Compatibility Profile on Biomaterials for Bone Regeneration
Published on: November 16, 2018
Biologic Responses to Orthopedic Implants: Innate and Adaptive Immune Responses to Implant Debris
1Department of Orthopedics, Department of Immunology, Department of Anatomy and Cell Biology, Rush University Medical Center, Chicago, IL.
Almost 20% of joint replacement implants fail at 15 to 20 years. Reports suggest that systemic effects of metal-on-metal implants and local effects of total joint arthroplasty implants contributing to implant failure are immune system based. Sometimes implant wear debris can cause implant failure resulting from bone fracture, infection, or implant fracture/failure; most often, aseptic osteolysis or loosening leads to wear debris. Debris is produced by wear (primary) or by corrosion. Corrosion-chemical oxidation comprising reduction reactions involving electron transport-produces electrochemical degradation. Metallic implant degradation occurs when electrochemical dissolution and mechanical/physical wear are combined (i.e., tribocorrosion). With metal-on-metal implants, even with relatively low levels of wear and particle release, pathology caused by metal debris such as pseudotumor/fibrous tissue growth can lead to early implant failure.
Almost 20% of joint replacement implants fail at 15 to 20 years. Reports suggest that systemic effects of metal-on-metal implants and local effects of total joint arthroplasty implants contributing to implant failure are immune system based. Sometimes implant wear debris can cause implant failure resulting from bone fracture, infection, or implant fracture/failure; most often, aseptic osteolysis or loosening leads to wear debris. Debris is produced by wear (primary) or by corrosion. Corrosion-chemical oxidation comprising reduction reactions involving electron transport-produces electrochemical degradation. Metallic implant degradation occurs when electrochemical dissolution and mechanical/physical wear are combined (i.e., tribocorrosion). With metal-on-metal implants, even with relatively low levels of wear and particle release, pathology caused by metal debris such as pseudotumor/fibrous tissue growth can lead to early implant failure.
More Related Videos
07:55A Macrophage Reporter Cell Assay to Examine Toll-Like Receptor-Mediated NF-kB/AP-1 Signaling on Adsorbed Protein Layers on Polymeric Surfaces
Published on: January 7, 2020
08:37Polarization and Characterization of M1 and M2 Human Monocyte-Derived Macrophages on Implant Surfaces
Published on: December 6, 2024
Related Concept Videos
Cell-mediated Immune Responses
Introduction to Innate and Adaptive Immunity
Innate immunity is the body's natural, nonspecific defense system that acts quickly to protect against pathogens. It incorporates physical barriers like skin and mucous membranes and cellular elements such as phagocytes and natural killer cells. This part of our immune system provides an immediate,...
Inflammatory Response
Inflammation can be triggered by various stimuli, such as impact, abrasion, chemical irritation, infections, and extreme hot or cold temperatures. These can damage cells and connective tissue fibers,...
What is the Immune System?
Inflammatory Response I: Vascular and Cellular
Inflammatory Response II: Inflammatory Exudate and Tissue Repair
The typical wound exudate is odorless, transparent, straw-colored, thin, and watery. Exudate, however, can differ depending on the state of wound healing. Likewise, the...