Related Experiment Video

Updated: Mar 23, 2026

In Vivo Electrophysiological Measurements on Mouse Sciatic Nerves
11:07

In Vivo Electrophysiological Measurements on Mouse Sciatic Nerves

Published on: April 13, 2014

36.1K

In Vivo Magnetic Stimulation of Rat Sciatic Nerve With Centimeter- and Millimeter-Scale Solenoid Coils

Zachary B Kagan, Anil Kumar RamRakhyani, Gianluca Lazzi

    IEEE Transactions on Neural Systems and Rehabilitation Engineering : a Publication of the IEEE Engineering in Medicine and Biology Society
    |March 29, 2016
    PubMed

    Abstract:

    Previous reports of magnetic stimulation of the peripheral nervous system (PNS) used various coil geometries, all with outer diameters larger than 35 mm, and stimulation energies in the 50 J range to evoke neural excitation. Recent reports of central nervous system (CNS) activation used sub-mm-scale solenoid coils with mJ energy levels. The goal of this study was to translate the lower energy levels from the CNS to the PNS via using smaller coils placed in closer proximity to the neural tissue. Such a performance improvement would advance the state of the art of magnetic stimulation and provide a path towards new neuroprosthetic devices. Primarily, we investigated the range of coil outer diameters from 25 mm down to 5 mm to better understand the dependence of coil diameter on energy required for PNS activation. Nine cm- and mm-scale copper solenoid coils, with various resistances, inductances, inner and outer diameters, and heights were compared by quantizing neuromuscular responses to magnetic stimulation via capacitive discharge excitation of rat sciatic nerves in vivo. Additionally, the effects of stimulus duration and coil position were investigated. As opposed to prior work, this study compares a subset of stimulation parameters in an intact nerve preparation, and shows that magnetic stimulation with coils that abut the nerve is a reliable, effective method of neuromuscular stimulation. Although we observed different energies required for neuromuscular activation depending on the coil and excitation parameters used, for the experimental configuration, devices, and stimulus waveform shapes presented in this manuscript, no systematic dependence of PNS activation on coil diameter was found, even for the mm-scale coils investigated herein. However, there was a clear relationship between discharge circuit capacitance and energy required to evoke a neuromuscular response. Coils approximately 12 mm in outer diameter and larger consistently evoked responses, whereas coils 5 mm in outer diameter did not. Furthermore, we observed meaningful neuromuscular excitation when stimulating with energies as low as 20 J. Although this is an improvement over prior work, it is still orders of magnitude greater than the energy required for conventional electrical stimulation, suggesting that these devices are presently not suitable for use in an application requiring continued pulsed stimulation. Nevertheless, these devices are suitable for basic research and as clinical tools that infrequently stimulate, such as in diagnostic applications.

    More Related Videos

    Repetitive Transcranial Magnetic Stimulation to the Unilateral Hemisphere of Rat Brain
    05:47

    Repetitive Transcranial Magnetic Stimulation to the Unilateral Hemisphere of Rat Brain

    Published on: October 22, 2016

    13.1K
    In Vivo Intracellular Recording of Type-Identified Rat Spinal Motoneurons During Trans-Spinal Direct Current Stimulation
    11:07

    In Vivo Intracellular Recording of Type-Identified Rat Spinal Motoneurons During Trans-Spinal Direct Current Stimulation

    Published on: May 11, 2020

    5.8K

    Related Experiment Videos

    Last Updated: Mar 23, 2026

    In Vivo Electrophysiological Measurements on Mouse Sciatic Nerves
    11:07

    In Vivo Electrophysiological Measurements on Mouse Sciatic Nerves

    Published on: April 13, 2014

    36.1K
    Repetitive Transcranial Magnetic Stimulation to the Unilateral Hemisphere of Rat Brain
    05:47

    Repetitive Transcranial Magnetic Stimulation to the Unilateral Hemisphere of Rat Brain

    Published on: October 22, 2016

    13.1K
    In Vivo Intracellular Recording of Type-Identified Rat Spinal Motoneurons During Trans-Spinal Direct Current Stimulation
    11:07

    In Vivo Intracellular Recording of Type-Identified Rat Spinal Motoneurons During Trans-Spinal Direct Current Stimulation

    Published on: May 11, 2020

    5.8K

    Related Concept Videos

    Magnetic Field of a Solenoid01:18

    Magnetic Field of a Solenoid

    6.4K
    A solenoid is a conducting wire coated with an insulating material, wound tightly in the form of a helical coil. The magnetic field due to a solenoid is the vector sum of the magnetic fields due to its individual turns. Therefore, for an ideal solenoid, the magnetic field within the solenoid is directly proportional to the number of turns per unit length and the current. Conversely, the magnetic field outside the solenoid is zero.
    Consider a solenoid with 100 turns wrapped around a cylinder of...
    6.4K

    Articles linked to this work by shared authors, journal, and citation graph.

    Extraocular Electrical Stimulation Activates Retinal Ganglion Cells In Vivo.

    bioRxiv : the preprint server for biology·2026

    A spatially discretized convolutional neural mass model for studying meso-scale spatio-temporal transformations in the rat hippocampus.

    Journal of computational neuroscience·2026

    Impact of Aii Amacrine Cell Rewiring in a Pathoconnectome-Based Computational Model of Early Retinal Degeneration.

    bioRxiv : the preprint server for biology·2026

    A spatially discretized convolutional neural mass model for studying meso-scale spatio-temporal transformations in the rat hippocampus.

    Research square·2026

    SHARED-CONTROL DECREASES THE PHYSICAL AND COGNITIVE DEMANDS OF MAINTAINING A SECURE GRIP.

    Myoelectric Controls and Upper Limb Prosthetics Symposium·2026

    Serum drug levels and JCV assay discrepancies after switching from originator to biosimilar natalizumab.

    BMJ neurology open·2026

    Cross-Scale Transcranial Magnetic Stimulation Coil for Joint Control of Focal Position and Orientation.

    IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2026

    Quadra-Brain: Quadruplet Higher-Order Topological Representation Learning for fMRI-Based Brain Disorder Diagnosis.

    IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2026

    Using Digital Twins to Predict Recovery and Decline in Neurological Disorders.

    IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2026

    Personalized Gait Phase Estimation for Post-Stroke Individuals via Supervised Domain Adaptation with Limited Gait Data.

    IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2026

    Load-Decomposition Learning Enhances Ground Reaction Force Estimation Using IMUs.

    IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2026

    Nanopatterned Black Silicon Electrodes for High-Charge-Density Intraspinal Microstimulation.

    IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2026

    Measurement of radial electron density and temperature profile in the Wendelstein 7-X scrape off layer using the new outboard midplane thermal helium beam diagnostic.

    The Review of scientific instruments·2026

    Prediction of patient-specific quality assurance for volumetric modulated arc therapy using machine log files.

    Quantitative imaging in medicine and surgery·2026

    The inwardly pointing knee angle: A novel computed tomography-based measurement technique and validation study.

    Journal of experimental orthopaedics·2026

    Efficient Separation of Xe/Kr by Induced Polarization on Single-Atom Modified Ti3C2O2: A DFT Study.

    Chemphyschem : a European journal of chemical physics and physical chemistry·2026

    Pulmonary Artery Approach for Radiofrequency Catheter Ablation of Atrial Tachycardia Originating From Left Atrial Post Wall: A Case Report.

    Journal of cardiovascular electrophysiology·2026

    Long-term outcomes of splanchnic radiofrequency ablation for control of chronic abdominal visceral, non-malignant pain.

    Interventional pain medicine·2026
    See all related articles
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies
    Jove
    Visualize
    Contact Us