Composition and Distribution Analysis of Bioaerosols Under Different Environmental Conditions
Published on: January 7, 2019
Measuring Concentrations of Particulate 140La in the Air
Colin E Okada1, Warnick Kernan, Martin Keillor
1*United States Department of Energy/Remote Sensing Laboratory, Las Vegas, NV 89193; †United States Department of Energy/Pacific Northwest National Laboratory, Richland, WA.
Abstract:
Air sampling systems were deployed to measure the concentration of radioactive material in the air during the Full-Scale Radiological Dispersal Device Field Trials. The air samplers were positioned 100-600 m downwind of the release point. The filters were collected immediately and analyzed in a field laboratory. Quantities for total activity collected on the air filters are reported along with additional information to compute the average or integrated air concentrations.