Related Experiment Video
Updated: Mar 23, 2026

Ex Vivo Assessment of Contractility, Fatigability and Alternans in Isolated Skeletal Muscles
Published on: November 1, 2012
The Etiology of Muscle Fatigue Differs between Two Electrical Stimulation Protocols
Alain Martin1, Sidney Grosprêtre, Christophe Vilmen
11Aix-Marseille University, CNRS, Center for Magnetic Resonance in Biology and Medicine (CRMBM) UMR 7339, Marseille, FRANCE; 2INSERM, Cognition, Action, and Sensorimotor Plasticity (CAPS) UMR 1093, University of Burgundy, Faculty of Sport Sciences, Dijon, FRANCE; 3APHM, La Timone Hospital, Imaging Center, CEMEREM, Marseille, FRANCE; and 4Deparment of Rheumatology, Sainte Marguerite Hospital, Marseille, FRANCE.
Purpose:
This study aimed at investigating the mechanisms involved in the force reduction induced by two electrical stimulation (ES) protocols that were designed to activate motor units differently.
Methods:
The triceps surae of 11 healthy subjects (8 men; age, ~28 yr) was activated using ES applied over the tibial nerve. Two ES protocols (conventional [CONV]: 20 Hz, 0.05 ms vs wide-pulse high-frequency [WPHF]: 80 Hz, 1 ms) were performed and involved 40 trains (6 s on-6 s off) delivered at an intensity (IES) evoking 20% of maximal voluntary contraction. To analyze the mechanical properties of the motor units activated at IES, force-frequency relation was evoked before and after each protocol. H-reflex and M-wave responses evoked by the last stimulation pulse were also assessed during each ES protocol. Electromyographic responses (∑EMG) were recorded after each train to analyze the behavior of the motor units activated at IES. Metabolic variables, including relative concentrations of phosphocreatine and inorganic phosphate as well as intracellular pH, were assessed using P-MR spectroscopy during each protocol.
Results:
Larger H-reflex amplitudes were observed during WPHF as compared with CONV, whereas opposite findings were observed for M-wave amplitudes. Despite this difference, both the force reduction (-26%) and metabolic changes were similar between the two protocols. The CONV protocol induced a rightward shift of the force-frequency relation, whereas a significant reduction of the ∑EMG evoked at IES was observed only for the WPHF.
Conclusions:
These results suggest that a decreased number of active motor units mainly contributed to WPHF-induced force decrease, whereas intracellular processes were most likely involved in the force reduction occurring during CONV stimulation.
Related Concept Videos
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Muscle Recovery and Fatigue
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
Relaxation of Skeletal Muscles
When an action potential reaches the axon terminal, it depolarizes the membrane and opens voltage-gated sodium channels. Sodium ions enter the cell, further depolarizing the presynaptic membrane. This depolarization causes voltage-gated calcium channels to open....
Generation of Action Potential in Skeletal Muscles
Like neurons, muscle cells are also regarded as excitable due to their capacity to change in response to stimuli, primarily due to voltage-gated ion channels embedded in their plasma membranes, which get activated by alterations in the...
Energy Supply for Muscle Contraction