Related Experiment Video
Updated: Mar 23, 2026

Calibration Procedures for Orthogonal Superposition Rheology
Published on: November 18, 2020
Vibrational spectroscopy to support the link between rheology and continuous twin-screw melt granulation on molecular
Tinne Monteyne1, Liza Heeze1, Klaus Oldörp2
1Laboratory of Pharmaceutical Process Analytical Technology, Department of Pharmaceutical Analysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium.
Abstract:
Twin screw hot melt granulation (TSHMG) is an innovative and continuous drug formulation process allowing granulation of moisture sensitive drugs. However, due to the lack of experience and in-depth process understanding, this technique is not yet widely used. During the TSHMG process, the microstructure of the granules is generated and modified and strongly depends on the flow behavior of the material. Hence, rheology might be a suitable tool to simulate and examine this process. However, chemical interactions of the material are influencing the physical properties leading to the microstructure. In this research project it is spectroscopically investigated whether the heat applied in a rheometer induces the same molecular effects as these occurring during TSHMG of the model formulation caffeine anhydrous/Soluplus®. Hence, it is evaluated whether rheology can be used as a simulation tool to improve the understanding of the material behavior at molecular level during continuous melt granulation. Therefore, in-line Raman spectroscopy is executed during TSHMG and in situ Fourier Transform Infra-red (FTIR) during oscillatory rheological experiments. The results from the in-line Raman monitoring revealed polymorph transition of caffeine anhydrous during twin screw melt granulation with Soluplus® which is stimulated depending on the binder concentration and/or granulation temperature. A correlation was seen between the FTIR spectra obtained during the rheological temperature ramp and the in-line collected Raman spectra during the melt granulation runs. The polymorphic conversion of caffeine anhydrous could be detected in the same temperature range with both techniques, proving the comparability of plate-plate rheometry and hot melt granulation (HMG) for this case with the used parameter settings. Process simulation using rheology combined with in situ FTIR seems a promising approach to increase process understanding and to facilitate binder and parameter selection for TSHMG.
Related Concept Videos
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...

