Related Experiment Video
Updated: Mar 23, 2026

A New Murine Model of Endovascular Aortic Aneurysm Repair
Published on: July 7, 2013
Renal Stent Crushed During Open Aneurysmorrhaphy for Endoleak After Fenestrated EVAR
Islah Ud Din1, Usman Shaikh2, Robert K Fisher3
1Radiology Department, Royal Liverpool University Hospital, Liverpool, UK idin@nhs.net.
Purpose:
To report a complication of renal stent crushing during open aneurysmorrhaphy performed 10 years after fenestrated endovascular aneurysm repair (FEVAR).
Case Report:
A 67-year-old male patient underwent elective FEVAR of a juxtarenal aortic aneurysm. Uncovered balloon-expandable stents were placed through the fenestrations for the superior mesenteric and right renal arteries; the left renal artery received a Jostent covered balloon-expandable stent. The uncovered right renal stent was noted to be crushed on the first imaging after FEVAR, but was left untreated; the right kidney was thereafter significantly smaller than the left. Over several years, the aneurysm expanded, and type II endoleak involving the lumbar arteries was embolized with coils 7 years after FEVAR. Despite this, the aneurysm continued to enlarge and reached a diameter of 12.8 cm. Open aneurysmorrhaphy and selective ligation of lumbar arteries was performed 10 years after FEVAR. The first surveillance imaging after aneurysmorrhaphy demonstrated a new finding of a crushed left renal stent, which was presumed to be related to surgical instrumentation. The stent was successfully redilated percutaneously, and renal function remained stable. Computed tomography demonstrated a normal appearance of the left renal covered stent after re-expansion. Doppler ultrasound after 7.5 months showed normal renal perfusion.
Conclusion:
Balloon-expandable visceral artery stents are susceptible to crush injury during aortic surgery. Consideration should be given to early imaging after such surgery in FEVAR patients.
More Related Videos
07:21Microsurgical Creation of Giant Bifurcation Aneurysms in Rabbits for the Evaluation of Endovascular Devices
Published on: September 8, 2023
11:07Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique
Published on: October 1, 2017
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm IV: Nursing Management
Aneurysm I: Introduction