Related Experiment Video
Updated: Mar 23, 2026

Real-Time Electrocardiogram Monitoring During Treadmill Training in Mice
Published on: May 5, 2022
Electrocardiographic Eligibility for Subcutaneous Implantable Cardioverter Defibrillator: Evaluation during Bicycle
Matteo Ziacchi1, Alessandro Corzani1, Igor Diemberger1
1Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S.Orsola-Malpighi University Hospital, Bologna, Italy.
Background:
The subcutaneous implantable cardioverter-defibrillator (S-ICD) is used in patients at risk of sudden death. Our aim was to assess clinical predictors of electrocardiographic ineligibility for S-ICD, and the impact of exercise on S-ICD eligibility in an unselected series of patients requiring ICD therapy.
Methods:
102 patients at risk of sudden death were evaluated at rest and during exercise. Electrocardiograph screening using limb lead electrodes (to simulate the S-ICD sensing vectors) was performed at rest and during bicycle ergometer exercise.
Results:
R wave amplitude in lead D3 during exercise >16mV, baseline QTc and the sum of amplitudes of the R waves at supine >30mV were predictors of ineligibility for S-ICD. Eligibility increased from 90% to 100% of patients when evaluated with an "any of the three leads" criterion compared to current recommendations. A more restrictive criterion based on two of three ECG leads caused an eligibility drop at 66%, that further decreased to 56% during exercise; these figures improved to 79% and 81%, respectively, when an "any 2 of 3 leads" criterion was used.
Conclusions:
Huge ECG amplitude and QTc duration are associated with ineligibility in the current S-ICD release. By performing exercise testing, lead suitability changes in one patient out of 14 (7% of tested patients) and eligibility is decreased by use of a more stringent criterion for eligibility (ECG criteria satisfied in two of three leads). A dynamic selection of sensing vectors aiming at situation-specific suitability (any of three leads) would increase S-ICD eligibility to 100% of patients.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Dysrhythmias V: Evaluating Dysrhythmias
Cardiopulmonary Resuscitation III: AED Use