High-definition Fourier Transform Infrared FT-IR Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
FTIR spectroscopic imaging and mapping with correcting lenses for studies of biological cells and tissues
James A Kimber1, Liberty Foreman2, Benjamin Turner1
1Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, UK. s.kazarian@imperial.ac.uk.
Abstract:
Histopathology of tissue samples is used to determine the progression of cancer usually by staining and visual analysis. It is recognised that disease progression from healthy tissue to cancerous is accompanied by spectral signature changes in the mid-infrared range. In this work, FTIR spectroscopic imaging in transmission mode using a focal plane array (96 × 96 pixels) has been applied to the characterisation of Barrett's oesophageal adenocarcinoma. To correct optical aberrations, infrared transparent lenses were used of the same material (CaF2) as the slide on which biopsies were fixed. The lenses acted as an immersion objective, reducing scattering and improving spatial resolution. A novel mapping approach using a sliding lens is presented where spectral images obtained with added lenses are stitched together such that the dataset contained a representative section of the oesophageal tissue. Images were also acquired in transmission mode using high-magnification optics for enhanced spatial resolution, as well as with a germanium micro-ATR objective. The reduction of scattering was assessed using k-means clustering. The same tissue section map, which contained a region of high grade dysplasia, was analysed using hierarchical clustering analysis. A reduction of the trough at 1077 cm(-1) in the second derivative spectra was identified as an indicator of high grade dysplasia. In addition, the spatial resolution obtained with the lens using high-magnification optics was assessed by measurements of a sharp interface of polymer laminate, which was also compared with that achieved with micro ATR-FTIR imaging. In transmission mode using the lens, it was determined to be 8.5 μm and using micro-ATR imaging, the resolution was 3 μm for the band at a wavelength of ca. 3 μm. The spatial resolution was also assessed with and without the added lens, in normal and high-magnification modes using a USAF target. Spectroscopic images of cells in transmission mode using two lenses are also presented, which are necessary for correcting chromatic aberration and refraction in both the condenser and objective. The use of lenses is shown to be necessary for obtaining high-quality spectroscopic images of cells in transmission mode and proves the applicability of the pseudo hemisphere approach for this and other microfluidic systems.
More Related Videos
14:14Visualization of Cortex Organization and Dynamics in Microorganisms, using Total Internal Reflection Fluorescence Microscopy
Published on: May 1, 2012
10:26Soft Lithographic Procedure for Producing Plastic Microfluidic Devices with View-ports Transparent to Visible and Infrared Light
Published on: August 17, 2017
Related Concept Videos
Total Internal Reflection Fluorescence Microscopy
Applications of IR Spectroscopy: Overview
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...