Plastic Blood Gas Syringes and Measurement Error in Central Venous Oxygen Saturations
Rashmi Ghanpur1, John Santamaria, Barry Dixon
1Department of Critical Care, St Vincent's Hospital, Melbourne, Australia.
Objectives:
Measurement of central venous oxygen (SvO2) levels remains an important method for the detection of circulatory shock. Plastic blood gas syringes have supplanted glass. These syringes are, however, permeable to atmospheric oxygen. Common sampling practices, including a delay between blood aspiration and analysis and continuous mixing of the sample, may promote equilibration of the blood sample with atmospheric oxygen and could result in over estimation of SvO2 levels.
Methods:
Pulmonary artery or central venous catheter blood samples were taken from 21 critically ill patients. Two venous blood gas samples were collected simultaneously in plastic syringes. One sample was continuously mixed through a gentle rotation. The other sample was not mixed. Blood gas analyses were undertaken on both samples at baseline and at 5, 10, 15, and 20 min.
Results:
Compared with baseline levels, the SvO2 increased significantly over time for both continuously mixed and nonmixed samples (P < 0.0001). The rate of the increase was 2-fold greater for continuously mixed samples (P < 0.0001). For continuously mixed samples, the SvO2 was 63% at baseline, 65% at 5 min, 70% at 10 min, 74% at 15 min, and 78% at 20 min. For the nonmixed samples, the levels were 63%, 64%, 66%, 68%, and 70%, respectively.
Conclusions:
This is the first report documenting that plastic blood gas syringes systematically overestimate SvO2 levels when there is a delay in analysis or continuous mixing of the sample. Overestimation of SvO2 levels may harm patients as circulatory shock may not be recognized and treated.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:38Design and Development of a Model to Study the Effect of Supplemental Oxygen on the Cystic Fibrosis Airway Microbiome
Published on: August 3, 2021
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Errors occurring during blood pressure monitoring
Several factors...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...