Related Experiment Video
Updated: Mar 22, 2026

Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
Readmissions Following Implantation of a Continuous-Flow Left Ventricular Assist Device
Matthew Da Silva1, Jane MacIver1, Marnie Rodger1
1Peter Munk Cardiac Centre, Toronto General Hospital, University Health Network, University of Toronto, Toronto, Ontario, Canada.
Objective:
The objective of this study is to review and analyze readmission data for patients who received a continuous flow left ventricular assist device (LVAD).
Methods:
A retrospective review of 88 patients implanted with a continuous-flow LVAD between June 2006 and June 2014 was performed. Reason for readmission, frequency, length of stay, and procedures performed during each readmission were recorded. All patients were followed in our LVAD clinic and all readmissions were reported to our program.
Results:
Sixty-seven patients (76%) were discharged following their hospitalization for LVAD implant. In these patients, indication for LVAD support consisted of bridge to transplant (78%) and destination therapy (22%). Total device support time was 30,482 days, with an average support time of 455 ± 376 days. Forty-two patients (63%) were readmitted at least once, with an average length of readmission stay of nine days (median = 6). There were 129 readmissions totaling 1264 hospital days. The main reason for readmission was infection (17%). Despite this relatively high readmission rate, patients spent 86% of their time outside the hospital.
Conclusion:
Although common, LVAD readmissions can be appropriately managed with patients spending the majority of their support time at home. doi: 10.1111/jocs.12744 (J Card Surg 2016;31:361-364).