Related Experiment Video
Updated: Mar 22, 2026

Pre-Implantation Genetic Testing for Aneuploidy on a Semiconductor Based Next-Generation Sequencing Platform
Published on: August 17, 2022
Evaluation of the Early Access STR Kit v1 on the Ion Torrent PGM™ platform
Fei Guo1, Yishu Zhou2, Feng Liu3
1Criminal Science and Technology Institute of Liaoning Province, No. 2, Qishan Middle Road, Huanggu District, Shenyang, Liaoning 110032, PR China; Department of Forensic Medicine, National Police University of China, No. 83, Tawan Street, Huanggu District, Shenyang, Liaoning 110854, PR China.
Abstract:
The Early Access STR Kit v1 is designed to detect 25-plex loci with next generation sequencing (NGS) technology on the Ion Torrent PGM™ platform, including 16 of 20 expanded Combined DNA Index System (CODIS) core loci (CSF1PO, D1S1656, D2S1338, D2S441, D3S1358, D5S818, D7S820, D8S1179, D10S1248, D13S317, D16S539, D19S433, D21S11, TH01, TPOX and vWA), 8 non-CODIS core loci (D1S1677, D2S1776, D4S2408, D5S2500.AC008791, D6S1043, D6S474, D9S2157 and D14S1434) and Amelogenin. In this study, we compared the Early Access STR Kit v1 with the Ion Torrent™ HID STR 10-plex to find out its improvements and explored an appropriate analytical threshold to enhance the performance. In addition, seven experiments were conducted to evaluate the Early Access STR Kit v1 such as studies of repeatability, concordance, sensitivity, mixtures, degraded samples, case-type samples and pedigrees. Other than a little discordance (0.95%) with CE-STR results observed at D21S11, NGS-STR results correctly reflected the sample being tested. Repeatable results were obtained from both initial PCRs and emPCRs aside from a few variations of allele coverage. Full profiles could be obtained from 100pg input DNA and >48.84% profiles from 10pg input DNA. Mixtures were easily detected at 9:1 and 1:9 ratios. This system could be adapted to case-type samples and degraded samples. As a whole, the Early Access STR Kit v1 is a robust, reliable and reproducible assay for NGS-STR typing and a potential tool for human identification.
Related Concept Videos
Ion Exchange
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Clamper Circuit
Within this circuit, the diode's orientation prompts the capacitor to charge up to the level of the most negative peak of the input signal. Upon reaching this state, the diode ceases to...
Maximum Power Transfer
By substituting the entire circuit with...
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...

