Background:
Cardiac troponin is the preferred biomarker of myocardial injury. High-sensitivity troponin assays allow measurement of very low levels of troponin with excellent precision. After the introduction of a high-sensitivity troponin I assay the laboratory began to receive enquiries from clinicians about clinically discordant elevated troponin I results. This led to a systematic investigation and characterisation of the cause.
Methods:
Routine clinical samples were measured by the Architect High Sensitive Troponin-I (hsTnI) and the VITROS Troponin I ES assays (VitrosTnI). Results that were elevated according to the Architect but not the VITROS assay (Group 1) or results elevated by both assays but disproportionately higher on the Architect (Group 2) were re-analysed for hsTnI after re-centrifugation, multiple dilutions, incubation with heterophilic blocking reagents, polyethylene glycol (PEG) precipitation, and Protein A/G/L treatment. Sephacryl S-300 HR gel filtration chromatography (GFC) was performed on selected specimens.
Results:
A high molecular weight complex containing immunoreactive troponin I and immunoglobulin (macrotroponin I) was identified in 5% of patients with elevated hsTnI. Patients with both macrotroponin and myocardial injury had higher and longer elevation of hsTnI compared with VitrosTnI with peaks of both macrotroponin and free troponin I-C complex on GFC.
Conclusions:
Circulating macrotroponin I (macroTnI) causes elevated hsTnI results with the Architect High Sensitive Troponin-I assay with the potential to be clinically misleading. The assay involved in this investigation may not be the only assay affected by macrotroponin. It is important for laboratories and clinicians to be aware of and develop processes to identify and manage specimens with elevated results due to macrotroponin.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome I: Introduction
Acute Coronary Syndrome III: Diagnostic Studies
Myocarditis II: Clinical Features and Diagnostic Tests
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations