Related Experiment Video
Updated: Mar 22, 2026

Movement Retraining using Real-time Feedback of Performance
Published on: January 17, 2013
Towards reducing the impacts of unwanted movements on identification of motion intentions
Xiangxin Li1, Shixiong Chen1, Haoshi Zhang1
1Key Laboratory of Human-Machine Intelligence-Synergy Systems, Chinese Academy of Sciences (CAS), Shenzhen, Guangdong 518055, China; Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, CAS, Shenzhen, Guangdong 518055, China.
Abstract:
Surface electromyogram (sEMG) has been extensively used as a control signal in prosthesis devices. However, it is still a great challenge to make multifunctional myoelectric prostheses clinically available due to a number of critical issues associated with existing EMG based control strategy. One such issue would be the effect of unwanted movements (UMs) that are inadvertently done by users on the performance of movement classification in EMG pattern recognition based algorithms. Since UMs are not considered in training a classifier, they would decay the performance of a trained classifier in identifying the target movements (TMs), which would cause some undesired actions in control of multifunctional prostheses. In this study, the impact of UMs was systemically investigated in both able-bodied subjects and transradial amputees. Our results showed that the UMs would be unevenly classified into all classes of the TMs. To reduce the impact of the UMs on the performance of a classifier, a new training strategy that would categorize all possible UMs into a new movement class was proposed and a metric called Reject Ratio that is a measure of how many UMs is rejected by a trained classifier was adopted. The results showed that the average Reject Ratio across all the participants was greater than 91%, meanwhile the average classification accuracy of TMs was above 99% when UMs occurred. This suggests that the proposed training strategy could greatly reduce the impact of UMs on the performance of the trained classifier in identifying the TMs and may enhance the robustness of myoelectric control in clinical applications.
Related Concept Videos
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...

