Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Receiver Operating Characteristic Plot01:15

Receiver Operating Characteristic Plot

569
A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
569
Functional Classification of Joints01:09

Functional Classification of Joints

8.9K
Functional Classification of Joints
The functional classification of joints is determined by the amount of mobility between the adjacent bones. Joints are functionally classified as a synarthrosis or immobile joint, an amphiarthrosis or slightly moveable joint, or as a diarthrosis, a freely moveable joint. Fibrous and cartilaginous joints can be functionally classified as either synarthroses  or amphiarthroses, whereas all synovial joints are classified as diarthroses.
Synarthrosis
An...
8.9K
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

5.5K
In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
5.5K
Structural Classification of Joints01:20

Structural Classification of Joints

8.5K
Joints, also known as articulations, are classified based on their structural characteristics, i.e., based on whether the articulating surfaces of the adjacent bones are directly connected by fibrous connective tissue or cartilage, or whether the articulating surfaces contact each other within a fluid-filled joint cavity. These differences serve to divide the joints of the body into three structural classifications.
A fibrous joint is where the adjacent bones are united by fibrous connective...
8.5K
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

5.1K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
5.1K
Sensitivity, Specificity, and Predicted Value01:13

Sensitivity, Specificity, and Predicted Value

1.7K
In healthcare diagnostics, laboratory tests play a crucial role in identifying and diagnosing a wide range of medical conditions. However, interpreting test results is not always straightforward. An abnormal test result does not always confirm the presence of a disease, just as a normal result does not guarantee its absence. To assess the reliability of these diagnostic tools, healthcare practitioners rely on two key statistical indicators: sensitivity and specificity.
Sensitivity is the...
1.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Evaluating Time Occupancy and Time-Scales in Interference Testing with Pulse-Modulated Noise.

IEEE transactions on electromagnetic compatibility·2026
Same author

Finding the optimal recall rate in breast cancer screening: results from the ROCS study.

European radiology·2026
Same author

Correlation of Automated in Vivo Image Quality With Radiologist's Performance in Abdomen Computed Tomography Across Conventional and Deep Learning Reconstructions.

Journal of computer assisted tomography·2026
Same author

Use of Expected Utility to Evaluate Artificial Intelligence-Enabled Rule-out Devices for Mammography Screening.

Medical decision making : an international journal of the Society for Medical Decision Making·2025
Same author

Consistent performance between medical experts and non-expert readers in forced-choice lesion-detection tasks with PET images.

Medical physics·2025
Same author

Convolutional neural network model observers discount signal-like anatomical structures during search in virtual digital breast tomosynthesis phantoms.

Journal of medical imaging (Bellingham, Wash.)·2025

Related Experiment Video

Updated: Mar 22, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

43.8K

Optimal Joint Detection and Estimation That Maximizes ROC-Type Curves.

Adam Wunderlich, Bart Goossens, Craig K Abbey

    IEEE Transactions on Medical Imaging
    |April 20, 2016
    PubMed
    Summary

    This study introduces a unified Bayesian framework for joint detection-estimation tasks in medical imaging. The new approach optimizes various receiver operating characteristic (ROC)-type curves, enhancing observer performance analysis and imaging system development.

    More Related Videos

    Author Spotlight: AI-Driven Trypanosome Species Detection from Microscopic Images
    08:20

    Author Spotlight: AI-Driven Trypanosome Species Detection from Microscopic Images

    Published on: October 27, 2023

    2.8K
    Automated Joint Space Detection Improves Bone Segmentation Accuracy
    06:45

    Automated Joint Space Detection Improves Bone Segmentation Accuracy

    Published on: November 28, 2025

    264

    Related Experiment Videos

    Last Updated: Mar 22, 2026

    Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
    13:44

    Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

    Published on: August 30, 2013

    43.8K
    Author Spotlight: AI-Driven Trypanosome Species Detection from Microscopic Images
    08:20

    Author Spotlight: AI-Driven Trypanosome Species Detection from Microscopic Images

    Published on: October 27, 2023

    2.8K
    Automated Joint Space Detection Improves Bone Segmentation Accuracy
    06:45

    Automated Joint Space Detection Improves Bone Segmentation Accuracy

    Published on: November 28, 2025

    264

    Area of Science:

    • Medical Imaging
    • Statistical Decision Theory
    • Observer Performance Analysis

    Background:

    • Combined detection-estimation tasks are crucial in medical imaging for system optimization and performance evaluation.
    • Existing methods for joint detection and estimation lack a unified framework to handle various performance metrics.
    • Receiver operating characteristic (ROC)-type curves are standard for evaluating diagnostic accuracy but require adaptation for complex tasks.

    Purpose of the Study:

    • To present a unified Bayesian framework for decision rules in combined detection-estimation tasks.
    • To develop optimal decision rules that maximize various ROC-type summary curves.
    • To propose new ROC-type curves and decision rules for scenarios with an unknown number of signals.

    Main Methods:

    • Developed a unified Bayesian framework interpreting ROC-type curves as utility-disutility plots.
    • Derived a general utility structure leading to a linear expected utility equation.
    • Illustrated the framework with a known signal of unknown amplitude detection-estimation example.
    • Proposed new ROC-type summary curves and decision rules for unknown, multiple signal scenarios.

    Main Results:

    • The unified framework successfully encompasses and generalizes various ROC-type curves (ROC, LROC, EROC, FROC, AFROC, EFROC).
    • A linear expected utility equation was derived, simplifying decision rule formulation.
    • The proposed methods provide optimal decision strategies for joint detection-estimation.
    • New ROC-type curves and decision rules were introduced for complex, multi-signal scenarios.

    Conclusions:

    • The unified Bayesian framework offers a powerful and flexible approach to joint detection-estimation in medical imaging.
    • This framework provides a theoretical basis for optimizing observer performance and developing advanced imaging algorithms.
    • The proposed methods advance the analysis of complex detection-estimation tasks, particularly those involving multiple signals.