Purpose:
The purpose of this study was to evaluate the risk factors for tube exposure after glaucoma drainage implant surgery.
Patients And Methods:
This was a retrospective case-controlled observational study of 64 eyes from 64 patients. Thirty-two eyes of 32 patients with tube erosion requiring surgical revision were compared with 32 matched control eyes of 32 patients. Univariate and multivariate risk factor analyses were performed.
Results:
Mean age was significantly younger in the tube exposure group compared with the control group (48.2±28.1 years versus 67.3±18.0 years, respectively; P=0.003). The proportion of diabetic patients (12.5%) in the tube exposure group was significantly less (P=0.041) compared with the control group (37.5%). Comparisons of the type and position of the drainage implant were not significantly different between the two groups. The average time to tube exposure was 17.2±18.0 months after implantation of the drainage device. In both univariate and multivariate analyses, younger age (P=0.005 and P=0.027) and inflammation prior to tube exposure (P≤0.001 and P=0.004) were significant risk factors. Diabetes was a significant risk factor only in the univariate analysis (P=0.027).
Conclusion:
Younger age and inflammation were significant risk factors for tube exposure after drainage implant surgery.
More Related Videos
08:55Translaminar Autonomous System Model for the Modulation of Intraocular and Intracranial Pressure in Human Donor Posterior Segments
Published on: April 24, 2020
07:30Transcanalicular Diode Laser-assisted Dacryocystorhinostomy for the Treatment of Primary Acquired Nasolacrimal Duct Obstruction
Published on: October 13, 2017
Related Concept Videos
Glaucoma: Overview
Angle Closure Glaucoma: Treatment
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....