Related Experiment Video
Updated: Mar 22, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
[Correlation between a blood pressure variability-based scoring system and target organ damage in patients with
11Southern Medical University, Guangzhou 510515, China; 2Department of Cardiology, Guangzhou General Hospital of Guangzhou Military Command, Guangzhou 510010, China.
Insights
A new blood pressure variability scoring system (BPVSS) effectively indicates target organ damage in hypertension patients. Lower scores correlate with more severe heart and blood vessel damage, highlighting BPVSS as a valuable clinical tool.
Area of Science:
- Cardiology
- Hypertension Research
- Vascular Biology
Background:
- Hypertension is a major risk factor for cardiovascular diseases.
- Target organ damage is a key indicator of hypertension severity and prognosis.
- Assessing blood pressure variability (BPV) offers insights into cardiovascular risk.
Purpose of the Study:
- To evaluate the relationship between a novel blood pressure variability scoring system (BPVSS) and target organ damage in hypertensive patients.
- To determine if BPVSS can serve as a reliable indicator of subclinical organ damage.
Main Methods:
- A cohort of 95 essential hypertension inpatients was analyzed.
- Blood pressure variability indices were correlated with parameters of target organ damage, including interventricular septum thickness (IVSd), left ventricular posterior wall thickness (LVPWd), brachial-ankle pulse wave velocity (baPWV_L/R), and intima-media thickness (IMT_L/R).
- Patients were stratified into high (BPVSS ≥ 3.9) and low (BPVSS < 3.9) BPVSS groups for comparative analysis.
Main Results:
- BPVSS showed significant negative correlations with IMT_L/R, IVSd, LVPWd, and baPWV_L/R, indicating that higher BPV (lower BPVSS) is associated with increased organ damage.
- The low BPVSS group exhibited significantly higher IVSd, LVPWd, baPWV_L/R, and IMT_L/R compared to the high BPVSS group.
- A significantly higher proportion of carotid plaques was observed in the low BPVSS group.
Conclusions:
- The blood pressure variability scoring system (BPVSS) is a valuable tool for assessing the severity of target organ damage in hypertension.
- Elevated blood pressure variability, reflected by lower BPVSS scores, is associated with more pronounced cardiac and vascular damage.
- BPVSS can aid in risk stratification and management of hypertensive patients.
Objective:
To investigate the relationship between a blood pressure variability (BPV)-based scoring system (BPVSS) and the target organ damage in patients with hypertension.
Methods:
We selected 95 consecutive inpatients with essential hypertension admitted between January and June, 2015 in the Department of Cardiology of Guangzhou General Hospital of Guangzhou Military Command. The BPV indices were analyzed for their correlation with the parameters of target organ damage (IVSd, LVPWd, baPWV_L/R, and IMT_L/R). The patients with a BPVSS of 3.9 or higher (control, 43 cases) and those with a lower BPVSS (observation group, 52 cases) were compared for differences in IVSd, LVPWd, baPWV_L/R, IMT_L/R and the proportion of carotid plaques.
Results:
Similar with the traditional BPV indices, BPVSS was negatively correlated with IMT_L/R (r=-0.278/-0.324, P<0.05). BPVSS was also negatively correlated with IVSd (r=-0.241), LVPWd (r=-0.223), and baPWV_L/R (r=-0.468/-0.373) (P<0.05). IVSd, LVPWd, baPWV_L/R and IMT_L/R were all significantly higher in the observation group than in the control group (t=2.307, 2.516, 3.250/2.790, and 2.372/3.425, respectively; P<0.05). The proportion of carotid plaques in the observation group was significantly higher than that in the control group (Χ(2)=27.833, P<0.001).
Conclusion:
BPVSS indicates the severity of target organ damage in patients with hypertension. A greater BPV is correlated with a lower BPVSS score and more severe damages of the heart and blood vessels.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Hypertension III: Clinical Manifestations and Diagnostic Studies
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Hypertension and Regulation of Blood Pressure