Including sheath effects in the interpretation of planar retarding potential analyzer's low-energy ion data
L E Fisher1, K A Lynch1, P A Fernandes1
1Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire 03755, USA.
Abstract:
The interpretation of planar retarding potential analyzers (RPA) during ionospheric sounding rocket missions requires modeling the thick 3D plasma sheath. This paper overviews the theory of RPAs with an emphasis placed on the impact of the sheath on current-voltage (I-V) curves. It then describes the Petite Ion Probe (PIP) which has been designed to function in this difficult regime. The data analysis procedure for this instrument is discussed in detail. Data analysis begins by modeling the sheath with the Spacecraft Plasma Interaction System (SPIS), a particle-in-cell code. Test particles are traced through the sheath and detector to determine the detector's response. A training set is constructed from these simulated curves for a support vector regression analysis which relates the properties of the I-V curve to the properties of the plasma. The first in situ use of the PIPs occurred during the MICA sounding rocket mission which launched from Poker Flat, Alaska in February of 2012. These data are presented as a case study, providing valuable cross-instrument comparisons. A heritage top-hat thermal ion electrostatic analyzer, called the HT, and a multi-needle Langmuir probe have been used to validate both the PIPs and the data analysis method. Compared to the HT, the PIP ion temperature measurements agree with a root-mean-square error of 0.023 eV. These two instruments agree on the parallel-to-B plasma flow velocity with a root-mean-square error of 130 m/s. The PIP with its field of view aligned perpendicular-to-B provided a density measurement with an 11% error compared to the multi-needle Langmuir Probe. Higher error in the other PIP's density measurement is likely due to simplifications in the SPIS model geometry.
Related Concept Videos
π Electron Effects on Chemical Shift: Overview
Mass Analyzers: Common Types
π Electron Effects on Chemical Shift: Aromatic and Antiaromatic Compounds
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Atomic Emission Spectroscopy: Lab
Ion-Exchange Chromatography