Related Experiment Video
Updated: Mar 21, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Fracture toughness of chairside CAD/CAM materials - Alternative loading approach for compact tension test
Rania Badawy1, Omar El-Mowafy2, Laura E Tam2
1Department of Biomaterials, Faculty of Dentistry, Suez-Canal University, Ismailia, Egypt.
Objective:
This in-vitro study determined plane-strain fracture toughness (KIC) of five different chairside CAD/CAM materials used for crown fabrication, following alternative innovative loading approach of compact tension test specimens.
Methods:
Rectangular-shaped specimens were cut from CAD/CAM blocks (n=10): Vita Mark II (Vident) (VMII); Lava-Ultimate (3M/ESPE) (LU); Vita Enamic (Vident) (VE); IPS e.max CAD (Ivoclar Vivadent); crystallized and un-crystallized (E-max and E-max-U, respectively); and Celtra Duo (Dentsply) fired and unfired (CD and CD-U, respectively). Specimens were notched with thin diamond disk prior to testing. Instead of applying tensile loading through drilled holes, a specially-made wedge-shaped steel loading-bar was used to apply compressive load at the notch area in Instron universal testing machine. The bar engaged the top ¼ of the notch before compressive load was applied at a cross-head speed of 0.5mm/min. Fracture load was recorded and KIC calculated. Data was statistically-analyzed with one-way ANOVA at 95% confidence level and Tukey's tests.
Results:
Means and SDs of KIC in MPam(1/2) for VMII, LU, VE, E-max, E-max-U, CD and CD-U were: 0.73 (0.13), 0.85 (0.21), 1.02 (0.19), 1.88 (0.62), 0.81 (0.25), 2.65 (0.32) and 1.01 (0.15), respectively. ANOVA revealed significant difference among the groups (p<0.001). CD and E-max had significantly highest mean KIC values.
Significance:
Mean KIC values of the tested materials varied considerably, however, none of them reached mean KIC of dentin (3.08MPam(1/2)) previously reported. For E-max and CD, specimens firing significantly increased mean KIC. The modified test arrangement was found to be easy to follow and simplified specimen preparation process.
Related Concept Videos
Fatigue
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Stress-Strain Diagram - Brittle Materials
Yield Criteria for Ductile Materials under Plane Stress
The Maximum Shearing Stress Criterion, also known as...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...