Related Experiment Video
Updated: Mar 21, 2026

Quantifying Arms and Legs Contributions during Repetitive Electrically-Assisted Sit-To-Stand Exercise in Paraplegics: A Pilot Study
Published on: November 11, 2022
The Effect of the Gravity Loading Countermeasure Skinsuit Upon Movement and Strength
Philip A Carvil1, Julia Attias, Simon N Evetts
11Centre of Human & Aerospace Physiological Sciences, King's College London, London, United Kingdom; 2Wyle GmbH, Cologne, Germany; and 3RMIT University, Melbourne, Australia.
Abstract:
Carvil, PA, Attias, J, Evetts, SN, Waldie, JM, and Green, DA. The effect of the gravity loading countermeasure skinsuit upon movement and strength. J Strength Cond Res 31(1): 154-161, 2017-Effective countermeasures against musculoskeletal deconditioning induced by microgravity and disuse are required. A simple alternative to provision of artificial gravity by centrifugation is compressive axial loading. The Russian "Pingvin" suit was the first wearable suit to apply this concept using bungee cords tethered around the shoulders and feet. However, poor loading characteristics and severe thermal and movement discomfort were reported. The gravity loading countermeasure skinsuit (GLCS) uses a bidirectional weave to generate staged axial loading from shoulders to feet, better mimicking how Earth's gravity induces progressive loading head to foot. The Mk III GLCS's loading was evaluated and tolerability assessed during maximal joint motion, ambulation, and selected strength exercises. Eight subjects (5 male and 3 female; 28 ± 3 years; 179 ± 0.1 cm and 74.8 ± 2.9 kg), having given written informed consent, had an Mk III GLCS individually tailored. Axial loading imparted, body height, joint range of motion (ROM), ambulation, and strength tests (12 repetition maximum) were performed in the GLCS and gym attire, with subjective (rating of perceived exertion, thermal comfort, movement discomfort and body control) ratings recorded throughout. Gravity loading countermeasure skinsuit provided significant axial loading when standing but significantly reduced knee (-13°), spinal (-28°) and shoulder flexion/extension ROM (-34°/-13°), in addition to Sit and Reach (-12.8 cm). No thermal issues were reported but there was an increase in subjective discomfort. Gravity loading countermeasure skinsuit did not significantly impede strength exercise, with the exception of shoulder press. The GLCS (Mk III) demonstrates potential as a countermeasure by providing tolerable, static axial loading. Furthermore, it may serve as an elasticlike strength exercise adjunct, which may have utility as a rehabilitation modality after further design refinement.
Related Concept Videos
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Eccentric Loading

