Related Experiment Video
Updated: Mar 21, 2026

Genetic Variant Detection in the CALR gene using High Resolution Melting Analysis
Published on: August 26, 2020
Screening PCR Versus Sanger Sequencing: Detection of CALR Mutations in Patients With Thrombocytosis
Ji Hun Jeong1, Hwan Tae Lee1, Ja Young Seo1
1Department of Laboratory Medicine, Gachon University Gil Medical Center, Incheon, Korea.
Background:
Mutations in calreticulin (CALR) have been reported to be key markers in the molecular diagnosis of myeloid proliferative neoplasms. In most previous reports, CALR mutations were analyzed by using Sanger sequencing. Here, we report a new, rapid, and convenient system for screening CALR mutations without sequencing.
Methods:
Eighty-three bone marrow samples were obtained from 81 patients with thrombocytosis. PCR primers were designed to detect wild-type CALR (product: 357 bp) and CALR with type 1 (product: 302 bp) and type 2 mutations (product: 272 bp) in one reaction. The results were confirmed by Sanger sequencing and compared with results from fragment analysis.
Results:
The minimum detection limit of the screening PCR was 10 ng for type 1, 1 ng for type 2, and 0.1 ng for cases with both mutations. CALR type 1 and type 2 mutants were detected with screening PCR with a maximal analytical sensitivity of 3.2% and <0.8%, respectively. The screening PCR detected 94.1% (16/17) of mutation cases and showed concordant results with sequencing in the cases of type 1 and type 2 mutations. Sanger sequencing identified one novel mutation (c.1123_1132delinsTGC). Compared with sequencing, the screening PCR showed 94.1% sensitivity, 100.0% specificity, 100.0% positive predictive value, and 98.5% negative predictive value. Compared with fragment analysis, the screening PCR presented 88.9% sensitivity and 100.0% specificity.
Conclusions:
This screening PCR is a rapid, sensitive, and cost-effective method for the detection of major CALR mutations.