Investigation of fluoride removal from low-salinity groundwater by single-pass constant-voltage capacitive
Wangwang Tang1, Peter Kovalsky1, Baichuan Cao2
1School of Civil and Environmental Engineering, University of New South Wales, Sydney, New South Wales 2052, Australia.
Abstract:
Capacitive deionization (CDI) is attracting increasing attention as an emerging technology for the facile removal of ionic species from water. In this work, the feasibility of fluoride removal from low-salinity groundwaters by single-pass constant-voltage CDI was investigated and a model developed to describe the dynamic fluoride electrosorption behavior. Effects of operating parameters including charging voltage and pump flow rate as well as impact of fluoride and chloride feed concentrations on the effluent fluoride concentration and equilibrium fluoride adsorption capacity were studied and the obtained data used to validate the model. Using the validated model, the effects of various design parameters, including arrangement of multiple CDI cells, on fluoride removal were assessed. Single-pass constant-voltage CDI was found to be effective in removing fluoride from low-salinity groundwaters but, as expected, removal efficiency was compromised in waters of high salinity. The relatively simple electrosorption model developed here provided a satisfactory description of both fluoride removal and current evolution and would appear to be a useful tool for prediction of CDI performance over a range of operating conditions, cell arrangements and feed water compositions though scope for model improvement exists.
More Related Videos
07:28An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
09:15Light Enhanced Hydrofluoric Acid Passivation: A Sensitive Technique for Detecting Bulk Silicon Defects
Published on: January 4, 2016
Related Concept Videos
Factors Affecting Solubility
Dielectric Polarization in a Capacitor
MOS Capacitor
The metal gate is typically made from highly conductive materials such as aluminum or polysilicon. Beneath the metal gate lies a thin layer of...
Ion Exchange
Debye–Huckel–Onsager Conductance Equation
Capacitors
When a voltage source is connected to a capacitor, positive and negative charges accumulate on the opposite plates. This accumulation generates a potential difference that equals the product of the...