Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
An immobilized carboxyl containing metal-organic framework-5 stationary phase for open-tubular capillary
Tao Bao1, Pingxiu Tang2, Zhenkun Mao2
1Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, and Wuhan University School of Pharmaceutical Sciences, Wuhan 430071, China; State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 10080, China.
Abstract:
A novel capillary column with metal-organic framework-5 (MOF-5) as the stationary phase was prepared for open-tubular capillary electrochromatography (OT-CEC). To grow MOF-5, the fused-silica capillary was functionalized firstly using 3-aminopropyltriethoxysilane and glutaraldehyde as covalent linkers; and then MOF-5 would be immobilized on the inner wall of COOH-terminated capillary by epitaxial growth, to produce a MOF-5-modified capillary. The successful growth of MOF-5 has been characterized and confirmed by scanning electron microscopy, X-Ray diffraction and Fourier transform infrared spectra. The influence of pH value and methanol on electroosmotic flow (EOF) of the MOF-5-modified capillary column was investigated. The EOF showed a pH-dependent from anode to cathode. The immobilization of MOF-5 improved the interactions between analytes and layer on inner wall of the capillary. Excellent separations of substituted benzenes and acidic and basic analytes were obtained on the fabricated capillary columns. The MOF-5-modified capillary columns exhibited good repeatability, with relative standard deviations for intra-day, inter-day runs and column-to-column less than 1.87%, 3.53%, and 8.49%, respectively. Our successful application of MOF-5 paved the way for introducing series of dicarboxylate-based isoreticular MOFs to OT-CEC as novel stationary phase.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion Exchange
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Extraction: Advanced Methods