Related Experiment Video
Updated: Jul 21, 2026

Transcanalicular Diode Laser-assisted Dacryocystorhinostomy for the Treatment of Primary Acquired Nasolacrimal Duct Obstruction
Published on: October 13, 2017
Delayed Periorbital Abscess after Silicone Implant to Orbital Floor Fracture
Raj Dedhia1, Travis T Tollefson1
1Department of Otolaryngology-Head and Neck Surgery, University of California, Davis, Sacramento, California.
Abstract:
There is a lack of consensus regarding preferred implant materials for orbital floor fracture reconstruction, leading to surgeon- and institution-dependent preferences. A variety of implants are used for orbital floor fracture reconstruction, each with their own complication profile. Knowledge of different implant materials is critical to identifying complications when they present. We report a delayed periorbital abscess 5 years after orbital floor reconstruction using a silicone implant.