Related Experiment Video
Updated: Mar 21, 2026

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
Published on: October 17, 2013
Hemodynamic Testing of Patient-Specific Mitral Valves Using a Pulse Duplicator: A Clinical Application of
Azad Mashari1, Ziyad Knio2, Jelliffe Jeganathan3
1Department of Anesthesia, Critical Care, and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA; Department of Anesthesia and Pain Management, Toronto General Hospital, University Health Network, University of Toronto, Toronto, Canada.
Objective:
To evaluate the feasibility of obtaining hemodynamic metrics of echocardiographically derived 3-dimensional printed mitral valve models deployed in a pulse-duplicator chamber.
Design:
Exploratory study.
Setting:
Tertiary-care university hospital.
Participants:
Percutaneous MitraClip procedure patient.
Interventions:
Three-dimensional R-wave gated, full-volume transesophageal echocardiography images were obtained after deployment of the MitraClip device. A high-quality diastolic frame of the mitral valve was segmented using Mimics Innovation Suite and merged with a flange. The data were exported as a stereolithography (.stl) file, and a rigid 3-dimensional model was printed using a MakerBot Replicator 2 printer. A flexible silicone cast then was created and deployed in the pulse-duplicator chamber filled with a blood-mimicking fluid.
Measurements And Main Results:
The authors were able to obtain continuous-wave Doppler tracings of the valve inflow with a transesophageal echocardiography transducer. They also were able to generate diastolic ventricular and atrial pressure tracings. Pressure half-time and mitral valve area were computed from these measurements.
Conclusion:
This pulse duplicator shows promising applications in hemodynamic testing of patient-specific anatomy. Future modifications to the system may allow for visualization and data collection of gradients across the aortic valve.
More Related Videos
06:56Author Spotlight: Advancing Cardiac Procedure Testing Prior to Embarking on Large Animal Studies
Published on: August 25, 2023
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...