Related Experiment Video
Updated: Mar 21, 2026

Testing the Efficacy of Pharmacological Agents in a Pericardial Target Delivery Model in the Swine
Published on: July 7, 2016
Methadone prolongs cardiac conduction in young patients with cancer-related pain
Doralina L Anghelescu1, Rakesh M Patel2, Daniel P Mahoney3
1Member, Department of Pediatric Medicine, Division of Anesthesiology, St Jude Children's Research Hospital, Memphis, Tennessee; Director, Pain Management Service, St Jude Children's Research Hospital, Memphis, Tennessee.
Objective:
Methadone prolongs cardiac conduction, from mild corrected QT (QTc) prolongation to torsades de pointes and ventricular fibrillation, in adults. However, methadone use for pain and its effects on cardiac conduction have not been investigated in pediatric populations.
Methods:
A retrospective review of QTc intervals in patients receiving methadone analgesia was conducted. Medical records from a 4-year period (September 2006 to October 2010) at a pediatric oncology institution were reviewed, and correlations were tested between cardiac conduction and methadone dosage and duration of therapy, electrolyte levels, renal and hepatic dysfunction, and concurrent medications.
Results:
Of the 61 patients who received methadone, 37 met our inclusion criteria and underwent 137 electrocardiograms (ECGs). During methadone treatment, the mean QTc was longer than that at baseline (446.5 vs 437.55 ms). The mean methadone dose was 27.0±24.3 mg/d (range, 5-125 mg/d; median, 20 mg/d) or 0.47±0.45 mg/kg per day (range, 0.05-2.25 mg/kg per day; median, 0.37 mg/kg per day), and the mean duration of therapy was 49 days. The authors identified a correlation between automated and manual ECG readings by two cardiologists (Pearson r=0.649; p<0.0001), but the authors found no correlations between methadone dose or duration and concurrent QTc-prolonging medications, sex, age, electrolyte abnormalities, or renal or hepatic dysfunction.
Conclusion:
At a clinically effective analgesic dose, methadone dosage and duration were not correlated with QTc prolongation, even in the presence of other risk factors, suggesting that methadone use may be safe in pediatric populations. The correlation between automated and manual ECG readings suggests that automated ECG readings are reliable for monitoring cardiac conductivity during the reported methadone-dosage regimens.