Effect of Different Abutments and Connections in Deformation Crestal Bone
Alfredo Mikail Melo Mesquita1, Juliano H M Silva, Cintia Helena Cury Saraceni
1*Professor, Department of Prosthodontics, Paulista University (UNIP), São Paulo, Brazil. †Student of the Graduate Program, Master in Dental Clinics, Paulista University (UNIP), São Paulo, Brazil. ‡Head, Graduate Program in Dentistry (UNIP), Paulista University (UNIP), São Paulo, Brazil. §Professor, Department of Dental Materials and Prosthodontics, Paulista State University (UNESP), Özcan, Zürich, Switzerland. ¶Professor, Dental Materials Unit, Center for Dental and Oral Medicine, Clinic for Fixed and Removable Prosthodontics and Dental Materials Science, University of Zurich.
Statement Of Problem:
The use of Morse taper connections is increasing, but little is known about the biomechanical use of abutments and their use in fixed prostheses.
Purpose:
This study evaluated the transmission of load on the bone implant-supported dentures, varying the type of prosthetic connection and abutment.
Material And Methods:
Using 4 polyurethane models, 3 implants were inserted into each block, establishing the following groups: (a) external hexagon and Micro-Unit abutments; (b) external hexagon and UCLA abutment; (c) Morse taper and Micro-Unit abutments; and (d) Morse taper and UCLA abutments. The prosthetic structures were cast, and in a universal testing machine, load was applied midway between the implants, with cantilever intervals of 5, 10, 15, 20, and 25 mm. Data were analyzed by Mann-Whitney, Friedman, and Kruskal-Wallis tests (P < 0.05).
Results:
Regarding the prosthetic connection, there was no difference in the use of hexagonal or Morse taper, but the use of Micro-Unit abutment showed lower deformation values than UCLA for the 2 connections.
Conclusions:
The use of intermediate abutments affects the distribution of masticatory loads: the greater the length of the cantilever, the greater the surface deformation of the bone around the distal implant.
Related Concept Videos
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Plastic Deformations
Deformations in a Symmetric Member in Bending
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Deformations in a Transverse Cross Section
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity