Effects of human limb gestures on galvanic coupling intra-body communication for advanced healthcare system
Xi Mei Chen1,2, Sio Hang Pun1, Jian Feng Zhao3
1State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Avenida da Universidade, Taipa, Macau, China.
Background:
Intra-Body Communication (IBC), which utilizes the human body as the transmission medium to transmit signal, is a potential communication technique for the physiological data transfer among the sensors of remote healthcare monitoring system, in which the doctors are permitted to remotely access the healthcare data without interrupt to the patients' daily activities.
Methods:
This work investigates the effects of human limb gestures including various joint angles, hand gripping force and loading on galvanic coupling IBC channel. The experiment results show that channel gain is significantly influenced by the joint angle (i.e. gain variation 1.09-11.70 dB, p < 0.014). The extension, as well as the appearance of joint in IBC channel increases the channel attenuation. While the other gestures and muscle fatigue have negligible effect (gain variation <0.77 dB, p > 0.793) on IBC channel. Moreover, the change of joint angle on human limb IBC channel causes significant variation in bit error rate (BER) performance.
Conclusions:
The results reveal the dynamic behavior of galvanic coupling IBC channel, and provide suggestions for practical IBC system design.