Related Experiment Video
Updated: Mar 20, 2026

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Balloon-Assisted Tracking: A Solution to Severe Subclavian Tortuosity Encountered During Transradial Primary PCI
Surya Dharma1, Ian C Gilchrist2, Tejas Patel3
1Department of Cardiology and Vascular Medicine, University of Indonesia, National Cardiovascular Center, Harapan Kita, Jakarta, Indonesia.
Abstract:
Radial artery access is preferred over femoral access for primary percutaneous coronary intervention (PCI) in patients with acute ST-segment elevation myocardial infarction because of the reduction in access site complications and mortality associated with the radial artery access. Successful transradial primary PCI requires knowledge of techniques to handle unexpected severe subclavian artery tortuosity. Balloon-assisted tracking (BAT) is one technique developed to negotiate the tortuosity and loops in the upper extremity. However, the use of BAT in dealing with a severe subclavian loop during a transradial primary PCI procedure has never been reported. We described a case of transradial primary PCI with severe subclavian artery loop that was negotiated successfully by the BAT technique.