Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies for Cardiovascular System IV: CMRI01:21

Imaging Studies for Cardiovascular System IV: CMRI

506
Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
506
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

10.2K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
10.2K
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

525
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
525
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

1.1K
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
1.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Influence of frequency and pulse train duration on respiratory responses during transcutaneous phrenic nerve stimulation in humans.

Journal of neural engineering·2026
Same author

Erratum: Multivariate assessment of the central-cardiorespiratory network structure in neuropathological disease (2018<i>Physiol. Meas</i>.<b>39</b>074004).

Physiological measurement·2026
Same author

An ultra-sensitive multi-channel MEG system for the non-invasive single-trial detection of cortical population spikes.

Scientific reports·2026
Same author

Muscle anisotropy influences the phrenic nerve activation threshold in non-invasive electrical stimulation.

Medical & biological engineering & computing·2026
Same author

Characterization of a flexible cap for simultaneous OPM-MEG and EEG measurements.

Journal of neural engineering·2026
Same author

Cognitive and clinical associations with lesion load and EEG microstate alterations in multiple sclerosis.

Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society·2026
Same journal

RETRACTED: Zhang et al. A Novel Framework for Reconstruction and Imaging of Target Scattering Centers via Wide-Angle Incidence in Radar Networks. <i>Sensors</i> 2025, <i>25</i>, 6802.

Sensors (Basel, Switzerland)·2026
Same journal

Enhancing Unsupervised Multi-Source Domain Adaptation for Person Re-Identification via Mixture of Experts and Graph-Based Relation.

Sensors (Basel, Switzerland)·2026
Same journal

Development of an Instrumented Glove for Palmar Pressure Assessment in Kayakers.

Sensors (Basel, Switzerland)·2026
Same journal

Development and Experimental Validation of an Autonomous IoT-Based Monitoring System for Real-Time Water Quality Assessment in the Amazon River.

Sensors (Basel, Switzerland)·2026
Same journal

Semi-Supervised Adversarial Learning Framework for Controller Area Network Bus Intrusion Detection.

Sensors (Basel, Switzerland)·2026
Same journal

Smart Optimization Method for Safety Signs in Innovative Manufacturing Environments Integrating Industrial Field IoT Sensors and Knowledge Graphs.

Sensors (Basel, Switzerland)·2026
See all related articles

Related Experiment Video

Updated: Mar 20, 2026

Cardiac Magnetic Resonance Imaging at 7 Tesla
09:14

Cardiac Magnetic Resonance Imaging at 7 Tesla

Published on: January 6, 2019

12.4K

Optimal Magnetic Sensor Vests for Cardiac Source Imaging.

Stephan Lau1,2,3, Bojana Petković4, Jens Haueisen5,6

  • 1Institute of Biomedical Engineering and Informatics, Ilmenau University of Technology, P.O. Box 100565, D-98684 Ilmenau, Germany. stephan.lau@tu-ilmenau.de.

Sensors (Basel, Switzerland)
|May 28, 2016
PubMed
Summary
This summary is machine-generated.

Optimizing sensor placement in magnetocardiography (MCG) using new room-temperature sensors significantly improves the accuracy of mapping cardiac electrical activity. This research paves the way for wearable MCG diagnostic vests.

Keywords:
boundary element methodcardiovascular diseasesheartinverse problemsmagnetocardiography (MCG)magnetostaticsmatrix conditionparticle swarm optimizationsource analysiswearable multi-sensor systems

More Related Videos

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
10:17

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System

Published on: April 11, 2025

2.1K
Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
06:29

Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques

Published on: June 11, 2019

11.3K

Related Experiment Videos

Last Updated: Mar 20, 2026

Cardiac Magnetic Resonance Imaging at 7 Tesla
09:14

Cardiac Magnetic Resonance Imaging at 7 Tesla

Published on: January 6, 2019

12.4K
Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
10:17

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System

Published on: April 11, 2025

2.1K
Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
06:29

Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques

Published on: June 11, 2019

11.3K

Area of Science:

  • Biophysics
  • Biomedical Engineering
  • Cardiology

Background:

  • Magnetocardiography (MCG) offers non-invasive cardiac functional insights.
  • Advancements in room-temperature magnetic field sensors (magnetoresistive and optically pumped magnetometers) enable ultra-low sensitivity measurements of cardiac fields.
  • These sensors allow flexible placement around the torso.

Purpose of the Study:

  • To optimize the positions and orientations of magnetic sensors in a vest-like configuration.
  • To achieve robust reconstruction of cardiac electric current distributions.
  • To establish a potential standard for sensor placement in MCG.

Main Methods:

  • A set of 32 sensors was optimized on a torso model.
  • A 13-dipole cardiac source model was used under noise-free conditions.
  • Reconstruction robustness was assessed using the lead field matrix condition.

Main Results:

  • Optimization enhanced the lead field matrix condition by approximately two orders of magnitude compared to a regular anterior array.
  • Optimized sensor distributions covered the entire torso, with denser sampling anteriorly and posteriorly over the heart.
  • Sensors near the heart were predominantly oriented tangentially to the body surface.

Conclusions:

  • The optimized sensor setup significantly improves the robustness of cardiac current reconstruction.
  • This work could lead to standardized sensor placement for MCG.
  • Development of a wearable MCG vest for clinical diagnostics is facilitated.