Related Experiment Video
Updated: Mar 20, 2026

Home-Based Prescribed Pulmonary Exercise in Patients with Stable Chronic Obstructive Pulmonary Disease
Published on: August 24, 2019
Interobserver Reliability of Peripheral Muscle Strength Tests and Short Physical Performance Battery in Patients With
Francesc Medina-Mirapeix1, Roberto Bernabeu-Mora2, Eduardo Llamazares-Herrán3
1Department of Physical Therapy, University of Murcia, Murcia, Spain.
Objective:
To evaluate the interobserver reliability of the Short Physical Performance Battery (SPPB) and hand dynamometry when measuring isometric muscle strength in people with chronic obstructive pulmonary disease (COPD).
Design:
Reliability study. Each patient was assessed by a pulmonology physician and a physical therapist in 2 separate sessions 7 to 14 days apart (mean, 9.8±0.8d). Each rater was blinded to the other's results.
Setting:
Pneumology unit of a public hospital.
Participants:
Random sample of outpatients with stable COPD (N=30).
Interventions:
Not applicable.
Main Outcome Measures:
SPPB and muscle strength (kg) using electronic handgrip and handheld dynamometers. Reliability was assessed with intraclass correlation coefficients (ICCs), standard error of measurement values, and Bland-Altman plots. ICCs were calculated for the SPPB summary score and for its 3 subscales.
Results:
The ICCs for the overall reliability of the SPPB summary score and for grip and quadriceps strength were .82 (95% confidence interval [CI], .62-.91), .97 (95% CI, .93-.98), and .76 (95% CI, .49-.88), respectively. The standard error of measurement values were .55 points, 1.30kg, and 1.22kg, respectively. The mean differences between the rater's scores were near zero for grip strength and SPPB summary score measures. The ICCs for the SPPB subscales were .84 (95% CI, .66-.92) for the chair subscale, .75 (95% CI, .48-.88) for gait, and .33 (95% CI, -.42 to .68) for balance.
Conclusions:
Interobserver reliability was good for quadriceps and handgrip dynamometry and for the SPPB summary score and its chair stand and gait speed subscales. Both pulmonary physicians and physical therapists can obtain and exchange the scores. Because the reliability of the balance subscale was questionable, it is better to use the SPPB summary score.
More Related Videos
09:44Manual Muscle Testing: A Method of Measuring Extremity Muscle Strength Applied to Critically Ill Patients
Published on: April 12, 2011
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...