Related Experiment Video
Updated: Mar 20, 2026

Coordinate Mapping of Hyolaryngeal Mechanics in Swallowing
Published on: May 6, 2014
Reliability of the reflux finding score for infants in flexible versus rigid laryngoscopy
Maartje M J Singendonk1, Bas Pullens2, Jan A A van Heteren1
1Department of Pediatric Gastroenterology and Nutrition, Emma Children's Hospital, Academic Medical Center, Amsterdam, The Netherlands.
Objectives:
The Reflux Finding Score for Infants (RFS-I) was developed to assess signs of laryngopharyngeal reflux (LPR) in infants. With flexible laryngoscopy, moderate inter- and highly variable intraobserver reliability was found. We hypothesized that the use of rigid laryngoscopy would increase reliability and therefore evaluated the reliability of the RFS-I for flexible versus rigid laryngoscopy in infants.
Methods:
We established a set of videos of consecutively performed flexible and rigid laryngoscopies in infants. The RFS-I was scored twice by 4 otorhinolaryngologists, 2 otorhinolaryngology fellows, and 2 inexperienced observers. Cohen's and Fleiss' kappas (k) were calculated for categorical data and the intraclass correlation coefficient (ICC) was calculated for ordinal data.
Results:
The study set consisted of laryngoscopic videos of 30 infants (median age 7.5 (0-19.8) months). Overall interobserver reliability of the RFS-I was moderate for both flexible (ICC = 0.60, 95% CI 0.44-0.76) and rigid (ICC = 0.42, 95% CI 0.26-0.62) laryngoscopy. There were no significant differences in reliability of overall RFS-I scores and individual RFS-I items for flexible versus rigid laryngoscopy. Intraobserver reliability of the total RFS-I score ranged from fair to excellent for both flexible (ICC = 0.33-0.93) and rigid (ICC = 0.39-0.86) laryngoscopies. Comparing RFS-I results for flexible versus rigid laryngoscopy per observer, reliability ranged from no to substantial (k = -0.16-0.63, mean k = 0.22), with an observed agreement of 0.08-0.35.
Conclusion:
Reliability of the RFS-I was moderate and did not differ between flexible and rigid laryngoscopies. The RFS-I is not suitable to detect signs or to guide treatment of LPR in infants, neither with flexible nor with rigid laryngoscopy.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...