Risk factors for i.v. compounding errors when using an automated workflow management system

Yihong Deng1, Alex C Lin2, John Hingl3

  • 1University of Cincinnati Winkle College of Pharmacy, Cincinnati, OH.

Summary

Automated compounding of intravenous (IV) medication doses in pediatric hospitals has an error rate of 0.74%. Key risk factors for IV compounding errors include morning shifts, Sundays, critical care unit preparation, and technician compounding.

Related Concept Videos

Pharmaceutical Poisoning: Potential Scenarios01:26

Pharmaceutical Poisoning: Potential Scenarios

Pharmaceutical poisoning can occur through various channels, impacting an estimated 2 million hospitalized patients in the U.S. annually with serious adverse drug responses. These scenarios encompass both therapeutic uses, such as drug toxicity, where even standard dosages can lead to severe central nervous system depression, and non-therapeutic exposures, including accidental ingestion by children, and environmental and occupational exposures.Unintentional poisonings often involve exploratory...
57
Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
1.7K
Guidelines and Strategies for Safe Computer Charting01:18

Guidelines and Strategies for Safe Computer Charting

The guidelines and strategies provided by the American Nurses Association (ANA) and the Canadian Nurses Association (CNA) offer essential principles for ensuring safe and secure computer charting systems in healthcare settings. Let's break down each recommendation:
Maintain Confidentiality and Security:
3.1K
One-Compartment Open Model for IV Bolus Administration: General Considerations01:19

One-Compartment Open Model for IV Bolus Administration: General Considerations

The one-compartment model is a pharmacokinetic tool that models the body as a single, uniform compartment, facilitating the understanding of drug distribution and elimination. This model is particularly beneficial for intravenous (IV) bolus administration, where the drug rapidly circulates throughout the body.
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
899
Systematic Error: Methodological and Sampling Errors01:15

Systematic Error: Methodological and Sampling Errors

In the case of systematic errors, the sources can be identified, and the errors can be subsequently minimized by addressing these sources. According to the source, systematic errors can be divided into sampling, instrumental, methodological, and personal errors.
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
11.3K
Guidelines for Nursing Documentation I01:30

Guidelines for Nursing Documentation I

Quality documentation and reporting share essential characteristics that ensure they are practical and valuable resources for those who use them. These characteristics are:
Factual:  
The following points emphasize the significance of upholding accurate and unbiased documentation in healthcare.
2.5K