Related Experiment Video
Updated: Mar 20, 2026

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Surgeon's and Patient's Radiation Exposure Through Vertebral Body Cement Augmentation Procedures: A Prospective
Nicolas Lonjon1, Marine Le Corre1, Julien Le Roy2
1Department of Neurosurgery, Gui de Chauliac Hospital, Montpellier, France.
Objective:
Vertebral body cement augmentation as a treatment option for osteoporotic or traumatic fractures has become increasingly popular during the past decade. However, these surgical procedures require numerous fluoroscopic examinations, resulting in high radiation exposure for the patient and the surgical team. The aim of this study was to evaluate the level of radiation exposure of the spine surgeon and the patient during these percutaneous procedures.
Methods:
Forty-nine patients admitted for single- or 2-level vertebral compression fracture were prospectively included and treated with vertebral body cement augmentation. For each procedure, radiation dose was measured on the surgeon's whole body, lens, and extremities as well as patient irradiation. Each surgeon wore 2 thermoluminescent dosimeters to measure lens and extremities radiation exposure and 1 electronic personal dosimeter. Patient clinical and surgical data, effective dose to patient, and surgeon were analyzed.
Results:
Mean operative time was 31.5 ± 11.7 minutes. The average fluoroscopic time was 61.0 ± 27.1 seconds. The average whole-body radiation dose per procedure was 1.4 ± 2.1 μSv. The average equivalent dose to lens and extremities were 44 μSv and 59 μSv, respectively.
Conclusions:
Values of radiation doses for surgeon and patient were lower than those reported in the previous literature. The recommended annual dose limit is set to 500 mSv for extremities and 150 mSv for lens. According to our results, the exposure dose to the eye exceeds the annual limit after 3500 procedures. However, there is increasing concern among surgeons about radiation exposure, and there is still a need for solutions as preventive measures.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
09:29Author Spotlight: Improving Percutaneous Vertebroplasty Surgical Accuracy and Efficiency Through Advanced Puncture Techniques
Published on: August 9, 2024
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT