Related Experiment Video
Updated: Mar 20, 2026

Two-way Valorization of Blast Furnace Slag: Synthesis of Precipitated Calcium Carbonate and Zeolitic Heavy Metal Adsorbent
Published on: February 21, 2017
Phosphate recovery from anaerobic digester effluents using CaMg(OH)4
Xueyu Liu1, Zhonghou Xu2, Jianfeng Peng3
1State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environmental Sciences, Beijing 100012, China; College of Water Sciences, Beijing Normal University, Beijing 100875, China.
Abstract:
Dolomite lime (DL) (CaMg(OH)4) was used as an economical source of Mg(2+) for the removal and recovery of phosphate from an anaerobic digester effluent of a municipal wastewater treatment plant (MWWTP) wastewater. Batch precipitation results determined that phosphate was effectively reduced from 87 to less than 4mg-P/L when the effluent water was mixed with 0.3g/L of DL. The competitive precipitation mechanisms of different solids in the treatment system consisting of Ca(2+)-Mg(2+)-NH4(+)-PO4(3-)CO3(2-) were determined by comparing model predictions with experimental results. Thermodynamic model calculations indicated that hydroxyapatite (Ca10(PO4)6(OH)2), Ca4H(PO4)3∙3H2O, Ca3(PO4)2(beta), and Ca3(PO4)2(am2) were more stable than struvite (MgNH4PO3∙6H2O) and calcite (CaCO3). However, X-ray diffraction (XRD) analysis determined the formation of struvite and calcite minerals in the treated effluent. Kinetic experimental results showed that most of the phosphate was removed from synthetic effluent containing NH4(+) within 2hr, while only 20% of the PO4(3-) was removed in the absence of NH4(+) after 24hr of treatment. The formation of struvite in the DL-treated effluent was due to the rapid precipitation rate of the mineral. The final pH of the DL-treated effluent significantly influenced the mass ratio of struvite to calcite in the precipitates. Because more calcite was formed when the pH increased from 8.4 to 9.6, a pH range of 8.0-8.5 should be used to produce solid with high PO4(3-) content. This study demonstrated that DL could be used for effective removal of phosphate from the effluent and that resultant precipitates contained high content of phosphate and ammonium.
More Related Videos
Related Concept Videos
Factors Affecting Solubility
Washing, Drying, and Ignition of Precipitates
The Phosphorus Cycle
Precipitation and Co-precipitation
Qualitative Analysis
For instance, group IV...
Gravimetry: Inorganic And Organic Precipitating Agents